45
(2) Double-Stacking Storage Procedures
Inspect this generator when operation is poor to determine the fault/malfunction.
Request the authorized distributor where the generator was purchased to perform
maintenance if you cannot find any faults/malfunctions during inspection.
WARNING : INJURY
Always be sure to observe the following items when double stacking this generator in
a warehouse or similar location.
Check that the hood of this generator is not dented, and
that bolts are not loose or missing.
Set in a location with a flat hard floor capable of
withstanding the double-stacking weight.
Always be sure to use “Lifting Hook” when lifting up the
generator. Using other parts when lifting up the
generator could cause the result of falling.
Insert wood ties of the same size and that are wider
than this generator between each generator, and set
another generator on top of the ties.
Never stack more than two levels, and do not set a
generator on top that is larger in weight/size than that on
the bottom.
Do not operate the generator when it is double stacked.
WARNING : ELECTRIC SHOCK / INJURY
Do not touch output terminals or internal electric parts while the generator is
operating.
Do not open the check door when the power switch is in the ON position. It will cause
injury by rotating parts such as cooling fans and fan belt.
Always turn the power switch to the OFF
position and stop the engine, then close
and lock OPERATION PANEL DOOR before checking or maintaining the engine or
any equipment.
CAUTION : FIRE
Never allow flame to come closer to the generator.
CAUTION : BURNS
Do not touch the engine and muffler after stopping the engine as they are still
extremely hot.
12. Troubleshooting