Key Features

 

 

Features 

  Next generation condensate self-evaporation design without the need to 

pour water, and is environment friendly, and more energy-saving. 

  L type evaporator design, enabling a more compact and efficient body. 

  Simple and convenient installation of accessories such as exhaust pipe, 

etc. 

  Self-diagnosis function and 24h on/off timer function. 

  Very portable and convenient to move around due to the universal 

caster wheels. 

  Quiet design, which allows you to use even while sleeping while still 

providing a very powerful supply of air. 

  Wide angle of air output with auto swing function for horizontal louvers. 

  Air Outlet Port which automatically close after powering off to prevent 

dust from getting into the unit. 

  Compressor programmed with protective function of automatic restart 

after 3 minute time delay. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SPAE12W

Страница 1: ... quality mobile air conditioner from Shinco Before use please read this entire manual carefully for information regarding setting up your portable A C operating it and tips on regular maintenance For any problems please refer to the Limited Warranty Information at the back of the manual ...

Страница 2: ...s 2 Important Safety Precautions 3 Key Features 4 Parts Accessories 5 6 Control Panel 7 Remote Control 8 Installation 9 10 Operation 11 12 Drainage Operation 13 Maintenance 14 Troubleshooting 15 Miscellaneous 16 Quick Installation Guide 17 ...

Страница 3: ...hysical sensory or mental capabilities Someone with a lack of experience and knowledge of Air Conditioners should use the machine only after they have been given supervision or instruction concerning use of the air conditioner in a safe way as well as understanding the hazards involved Children should not play with the appliance and cleaning and user maintenance should not be done by children with...

Страница 4: ...diagnosis function and 24h on off timer function Very portable and convenient to move around due to the universal caster wheels Quiet design which allows you to use even while sleeping while still providing a very powerful supply of air Wide angle of air output with auto swing function for horizontal louvers Air Outlet Port which automatically close after powering off to prevent dust from getting ...

Страница 5: ...es Parts List 1 Guide strip 2 Control panel 3 Inlet grid 4 Exhaust pipe 5 Corner wheel 6 Handle 7 Filter 8 Buckle of power line 9 Drainage outlet 10 Power line with plug 11 Exhaust outlet 2 1 3 5 4 Fig 1 3 6 7 10 9 11 8 ...

Страница 6: ...s Accessory List and Fitment 1 Adjustable Exhaust Hose Length 11in 60in 1pc 2 Oblate Joint 1pc 3 Round Joint Diameter 6in 1pc 4 Adjustable Window Sealplate Length 22in 42in 1set 5 Screw Type A 5pc 6 Screw Type B 4pc Fig 2 ...

Страница 7: ...play will show current room temperature If light indicator is lit for it will display this information in Degrees Centigrade if light indicator is lit for it will display this information in Degrees Fahrenheit WATER FULL The indicator light will show when the internal bucket is full SLEEP The indicator light will show when the unit is in SLEEP mode SPEED Pressing this button can select different f...

Страница 8: ...s button to select COOL mode DRY Press this button to select DRY mode FAN Press this button to select FAN mode UP DOWN Press UP or DOWN to set temperature or adjust timer HIGH Press this button to select HIGH speed MID Press this button to select MID speed LOW Press this button to select LOW speed SLEEP Press this button to set SLEEP mode In SLEEP mode the fan speed is fixed as LOW and cannot be a...

Страница 9: ...Note The exhaust hose is 24in 67in long including adapter We recommend trying to keep the exhaust hose as short as possible to prevent a large buildup of hot air in the exhaust The exhaust hose included is specifically designed in accordance with the specification of this air conditioner Please do not use any other exhaust hoses of different lengths or materials as this could lead to inefficiencie...

Страница 10: ... 10 Installation Illustration of Installation Wall mounted Hose alignment Incorrect bending ig 11 Fig 12 Fig 13 Fig 10 Fig 11 ...

Страница 11: ...er press MODE to cycle through the modes and select DRY mode The corresponding indicator lamp to the selected mode shows what MODE is currently running While in DRY mode the Temperature and speed are not adjustable This function is to dehumidify the air The air temp may not be cool as the air coming out as in the COOL mode Running in DRY mode may result in water collecting in the bucket and becomi...

Страница 12: ... to 3 hours and then 1 hour increments from 3 hours up to 24 hours After setting the timer select the desired operating mode If set for COOL mode you can adjust the set temperature After the set time expires the air conditioner starts automatically and runs in the selected operating mode Adjusting the Timer If you need to change or adjust the ON or OFF TIMER after it has been set press the TIMER b...

Страница 13: ...ion or once the bucket is manually drained Manually drain the water by moving the air conditioner to the site where the water can be drained directly such as the toilet or a drain unscrew the nut in the bottom rear of the unit and pull out the water plug as shown in Fig 14 Drain all water in water bucket from drain outlet You may need to recline the A C back to completely drain the water from the ...

Страница 14: ...h carefully Once finished dry the filters away from direct sunlight Install filters to the original position in the direction as shown in Fig 15 o Re Install Filter 1 first and then Filter 2 Postseason storage If the air conditioner is not being used for a long time or being put into storage please make sure to keep these maintenance measures in mind Drain all water in water bucket from drain outl...

Страница 15: ...et at LOW Adjust mode to COOL Remove debris Remove the heat source Clean strainers Adjust Temperature Select appropriate speed Noise too large and shake Is the unit on even level ground Put the air conditioner on even ground Caution When the following abnormalities occur to the air conditioner shut down the unit and pull out the plug and contact us using the information on the Limited Warranty Inf...

Страница 16: ...collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance f...

Страница 17: ...w type Vertical Sliding Horizontal Sliding The installation kit can be used for both vertical and horizontal sliding windows For a more secure installation use type B screws to secure Sealplate A to window frame and or window 3 Connect flexible venting hose with the Round Joint Turn the Round Joint counter clockwise until it stops 4 Connect the Round Joint to the rear of the portable air condition...