Shimpo Instruments DT-326B Скачать руководство пользователя страница 1

The DT-326B is a portable, light-weight stroboscope utilizing su-

per bright CREE High Powered LED lamps. The DT-326B’s LED 

array provides a bright, stable strobe light over a wide measure-

ment range with a lifetime far exceeding xenon lit stroboscopes. 

Containing a rechargeable lithium battery, a single charge can 

last up to a full 12 hours of operation. The DT-326B is designed for 

speed and frequency measurements in motion and vibration anal-

ysis. It is ideal for predictive and preventive maintenance appli-

cations such as: motors, shafts, roto-gravure printing, extruders, 

blow molding, wire lettering and striping, engraving, pulse jets, 

water jets, fans, cams, gear teeth, belt inspections, fuel injectors, 

vibration analysis, audio speaker analysis, spindle spinning, cut-

ting blade timing and sharpness, plus many more in the printing, 

packaging, textile, automotive, cable, mining, steel, chemical, op-

tical, medical and shipbuilding industries.

DT-326B LED Stroboscope
Operation Manual

SHIMPO INSTRUMENTS

Use in flammable environments is prohibited. Use in this manner may 

result in fire or explosive.

Don’t look directly into the LED light Source. This may result in eye in-

jury.

Don’t use or store in the following environments. Direct sunshine con-

densation, dust or caustic.

Do not alter, or modify of improperly. Such action may cause damage 

and void warranty.

Operate with 0-35°C (32-95°F), 35-85% RH. Use outside of this range 

may alter operation of the unit.

Case may become excessively hot when used continuously for more 

than 2 hours. Mount unit on a tripod or other fixed device.

SPECIFICATIONS

Flash Rate Range: 60 to 120,000 FPM ; 1-2000 Hz

Accuracy: 0.01%±1 digit of F.S. @ 77° F (25°C)

Lux Rating (Approx.): 6000 FPM & 2.5°: Distance 8˝ (20 cm) 

5800 lx with 4˝ (100 mm) irradiation dia., Distance 20˝ (50 

cm) 1050 lx with 6˝ (152 mm) irradiation dia. 1500 FPM & 2.5°:

Distance 8˝ (20 cm) 6400 lx with 4˝ (100 mm) irradiation dia.,

Distance 20˝ (50 cm) 1125 lx with 6˝ (152 mm) irradiation dia.

Lamp Lifetime: Approximately 3~5 years depending on usage.

Display: Backlit LCD

Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM

= 1 FPM; 1~200 HZ = 0.01 Hz; 201~2000 = 0.1 Hz

Flash Duration: 0.1°- 2.5°

Phase Shift: 0-359°

Power Requirement: 100-240 VAC 50/60Hz

Battery: Lithium DC 10.8V 2000 mA

Battery Life: Approx. 12 hours depending on settings

Input Signal: 12 V Pulse Input

Input Signal Range: 60-120,000 FPM (1-2000 Hz)

Input pulse width: over 50 µs

Input Signal Flash Delay: 0-999 ms; 0-359°

Temperature Limits: 32-95°F (0-35°C)

Humidity Limits: 35 to 85% RH

Enclosure: ABS

Product Weight: 0.84 lb (380 g)

Package Weight: 3.50 lb (1.6 kg)

Dimensions: 8.2 x 2.8 x 2.4” (208 x 70 x 60 mm)

Approvals: CE

Warranty: 1 year

Included Accessories:  AC power adapter, Carrying Case

Operation Panel

1. POWER: Power on and off.

2. MODE: Select mode of operation: Internal/External/

Parameter Settings

3. SET: Scroll through parameter settings, Store setting values.

4. x2: Multiplies the flash rate/frequency by a factor of 2.

5. 1/2: Divides the flash rate/frequency by a factor of 2.

6. RATIO: Adjusts flash duration (flash pulse width) in Internal/

External modes.

7. “+”: Advance image forward 3 degrees at a time in internal

mode. In parameter setting mode, adjusts setting values.

8. “-”: Retard image backwards 3 degrees at a time in internal

mode. In parameter setting mode, adjusts setting values.

9. Dial: Set flash rate or frequency. CW: Increase flash rate/fre-

quency. CCW: Decrease flash rate/frequency. (Turn dial quickly

to drastically change value; Turn dial slowly to change value

by 1 digit.) In parameter setting mode, CW or CCW rotation

changes the setting value.

10: FPM/Hz: Select between FPM or Hz units of measure

1

2

3

4

7

9

8

10

5

6

1.800.561.8187 

[email protected]

-Direct.ca

Отзывы: