III. Working Conditions

The electric pump shall continuously work normally under the following conditions:

1. The environment ambient shall not 40

;

2. Liquid temperature: 0~+40

; liquid temperature of AWZB and PW: 0~+90

3. The PH value of the medium shall be between 6.5 - 8.5;

4.  The  volume  ratio  of  the  solid  impurity  in  the  medium  shall  not  exceed  0.1%  and  the 

particle size shall not exceed 0.2mm;

5.  The  voltage  and  frequency  of  the  power  supply  must  meet  the  rated  voltage  and 

frequency on the nameplate of the electric pump; the fluctuation range of the voltage is 

±

10% of 

the rated value.

Vortex-type  Micro  Clean  Water  Pumps  (hereinafter  referred  to  as  the  “electric  pump”) 

include:  SQm,  QB,  WZB, AWZB,  PW;  the  electric  pump  consists  of  the  motor,  water  pump  and 
seal these three parts. The motor is the asynchronous motor. The impeller structure of the vortex-
type pump  is the vortex type which  can  achieve  high  head.  WZB, AWZB and  PW have  the self-
priming  function  while  QB  and  SQm  do  not.  PW  and AWZB  are  equipped  with  the  auto  control 
system,  which  can  realize  the  water  discharge  once  you  open  the  outlet  valve  and  the  electric 
pump works and once you close the outlet valve, the electric pump will automatically stop working 
without  need  to  cut  off  the  power  artificially.  Between  the  pump  and  the  motor,  the  single 
mechanical seal is adopted and the O-ring is adopted at the fixed seam allowance for static seal.

PW-Z series automatic self-priming pumps are configured with flow switch, pressure switch 

and  circuit  board.  Pumps  can  collect  flow  and  pressure  data  through  flow  switch  and  pressure 
switch and automatically on/off after analysing by the circuit board. PW-Z series pumps have the 
functions of water-load protection, delay start and anti-jamming the pump is in the standby state.

II. Product Overview

3

Содержание AWZB

Страница 1: ...Models SQm QB WZB AWZB PW SERVICE MANUAL Vortex Type Micro Clean Water Pump...

Страница 2: ...Precautions II Product Introduction III Operating Conditions IV Structure Diagram V Pump Wiring Diagram VI Installation Diagram VII Instructions for Installation VIII Maintenance IX Troubleshooting C...

Страница 3: ...tive device and you should ground the pump reliably connect the grounding wire to the marked terminal at the grounding mark of the electric pump or cable as well as the power socket is connected to gr...

Страница 4: ...t When taking anti freezing measures for the water pump in winter do not cover combustibles on the motor or pump for anti freezing in case of causing re accident and be sure not to cover the thermal i...

Страница 5: ...hronous motor The impeller structure of the vortex type pump is the vortex type which can achieve high head WZB AWZB and PW have the self priming function while QB and SQm do not PW and AWZB are equip...

Страница 6: ...Box 14 Capacitor 15 Cable Pressing Plate 16 Stator Housing 17 Bearing 18 Rotor 19 Water Deflector 1 2 3 4 5 6 7 9 8 10 11 12 13 15 16 17 19 14 1 Stator 2 Connector 3 O ring 4 Mechanical Seal 5 Circli...

Страница 7: ...y Spring 10 Connector 11 O ring 12 Mechanical Seal 13 Impeller 14 Pump Body 15 Slotted Cheese Head Screws 16 Hexagon Head Bolts 17 Filter 18 Inlet Rubber Washer 19 20 Check Valve 21 Spring 22 Rubber W...

Страница 8: ...r Deflector 7 Rotor 8 Bearing 9 Wavy Spring 10 Connector 11 O ring 12 Mechanical Seal 13 Impeller 14 Pump Body 15 Slotted Cheese Head Screws 16 Hexagon Head Bolts 17 Filter 18 Inlet 19 Set Screw 20 Ca...

Страница 9: ...tion Screws 7 Rotor 8 Bearing 9 Wavy Spring 10 Handle 11 Metal Hose 12 Connector 13 Mechanical Seal 14 O ring 15 Impeller 16 Pump Body 17 Slotted Cheese Head Screws 18 Hexagon Head Bolts 19 20 Inlet 2...

Страница 10: ...Screw 6 Pump Cover 7 O ring 8 Impeller 9 Mechanical Seal 10 Elbow 11 Pressure Switch 12 Pressure Tank 13 Water Deflector 14 Connector 15 Bearing 16 Rotor 17 Stator 18 Cable Sheath 19 Stator Housing 20...

Страница 11: ...11 Connector 12 Water Deflector 13 Impeller 14 Mechanical Seal 15 O ring 16 Rotor 17 Bearing 18 Stator 19 Stator Housing 20 Foot 21 Wavy Spring 22 Rear Cover 23 Fan 24 Fan Housing 25 Capacitor 26 Cab...

Страница 12: ...asher 10 Stator 11 Handle 12 Cross Recessed Small Pan Head Screw 13 Capacitor 14 Cable Sheath 15 Cable 16 Countersunk Flat Head Screws 17 Erminal Box Cover 18 Cable Pressing Plate 19 Stator Housing 20...

Страница 13: ...acitor 1AWZB H1 PW Z Series AWZB PW Series N1 L1 L N VI Installation Schematic Diagram Tap Water Pressurization QB SQm WZB Series Main Winding Capacitor Subline Yellow Green Motor Secondary Winding Ma...

Страница 14: ...Roof Water Tower Indirect Pressure Water Supply Lifting Water from Well Suction Head Filter 12...

Страница 15: ...and avoid breakage and water leakage of the rubber tube resulted from its heating and deformation 3 After connecting the upper end of the inlet pipe and the inlet of the electric pump you should ensur...

Страница 16: ...es The electric pump should be installed at places where it is convenient for checking and maintenance and be kept dry and ventilated When installing the electric pump at narrow places you should inst...

Страница 17: ...FF Square Pressure Switch Adjusting Screw For three phase electric pump that needs to be equipped with an overload protector you should select the matching overload protector according to the current...

Страница 18: ...resistance shall not be lower than 5M otherwise you must take relative measures and use it when the requirements are reached 2 Before conducting any maintenance operation you should cut off the power...

Страница 19: ...d to check whether the pressure tank is lled with air if there is no air inside you need to re ll air into the pressure tank as per the pressure marked on the tag of the pressure tank Recycling of the...

Страница 20: ...he sealing elements with new ones 4 Adjust the installation height of the water pump 5 Check the exibility of the foot valve remove the stopper try to shorten the water inlet pipeline and reduce the s...

Страница 21: ...driver or wrench to slowly turn it in the direction to an appropriate position The electric pump is started frequently when water is used 1 The pressure uctuation range of the pipeline networks of the...

Страница 22: ...troller contact short circuit but the electric pump still cannot be started 1 Ask the professional personnel to properly turn up the pressure of the pressure switch if the electric pump still cannot w...