Installing electrical parts
Electric wires
Conversion adapter
A conversion adapter (EW-AD305) is required to connect the EW-SD50 to a component with an
E-TUBE port for the EW-SD300.
Electric wire (EW-SD300)
Electric wire (EW-SD50)
Conversion adapter (EW-AD305)
Connecting / disconnecting the electric wire
Be sure to use the SHIMANO original tool to remove and insert electric wires.
NOTICE
•
When connecting and disconnecting electric wires, do not forcibly bend the plug part.
It may result in a poor connection.
`
Connecting the electric wire (EW-SD300)
Connect the electric wire to the E-TUBE port.
1.
Set the plug of the electric wire to the TL-EW300.
If there is an alignment tab on the plug of the electric wire, check the shape of the
E-TUBE port you are trying to connect to, and set it aligned with the alignment tab.
Without alignment tab on plug
Groove
Guide