Shimadzu ATX-R Series Скачать руководство пользователя страница 40

B

E

FO

R

E

 

W

EI

G

H

IN

G

U

S

IN

G

 MOR

E

 C

O

N

VE
N

IE

N

TL

Y

M

AI

N

TE

N

A

NC
E

TR

O

U

BL

ES

H

O

O

TING

FO

R Y
O

U

IN

FORM

AT

IO

N

U

S

IN

G T
H

BA
LA

N

C

E

39

 

V

Continued on next page

*

 

To return to the 1d display...

Follow the above steps, and confirm on the 10D display in step 4.

 

„

Selecting the Decimal Point Display Symbol

The decimal point can be displayed as either "." (a period) or "," (a comma).

1

 

Press 

 twice shortly in the  

weighing mode.

This opens the main menu.

2

  Select decimal point display setting.

[TOOLS]

   

   

[SYSTEM]

 

   

[POINT]

3

  Select the decimal point display 

symbol.

To select "." (period):

   

[PERIOD]

 

To select "," (comma):

   

[COMMA]

   STAND

 ! !P!O!I!NT

 !P!E!R!I!O!D

 ! !C!O!M!M!A

*  This may not be displayed.

Содержание ATX-R Series

Страница 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Страница 2: ...sponding to Messages Turning the Power ON and OFF Changing the Password GLP Output Function Specifications Maintenance Parts List of Functions That Can Be used in Combination Menu Map Weighing Outputi...

Страница 3: ......

Страница 4: ...ard provided and send it to us by facsimile 2 Access our website and will in the details accordingly https www shimadzu com an contact index html Once you have completed the user registration procedur...

Страница 5: ...o page 6 Search for what you want to do Menu Map page 150 Search quickly for the menu option you want to use Table of Contents page 15 Search for information based on its order of appearance in the ma...

Страница 6: ...symbol shown in the figure below appears at the head of the next page Index Notes Information to help use the balance correctly Explanation of terms The title of the previous page appears here Menu o...

Страница 7: ...f a number of different samples items to be weighed powder liquid etc and to mix these samples according to a formula Formulation page 102 n I want to check excess or deficiency with respect to a targ...

Страница 8: ...either immediately or after stabilization Output Timing Change Function page 131 n I want to change the format of the decimal point comma or period in the output data Selecting the Decimal Point Displ...

Страница 9: ...moderate injury or equipment damage Precautions Provides additional information needed to properly use the balance Descriptions of the other pictograms used within the instruction manual are listed be...

Страница 10: ...he product could operate abnormally Prohibitions Avoid locations where the balance will be exposed to volatile gas flammable gas or corrosive gas Failure to observe this may result in the outbreak of...

Страница 11: ...ay result in fingers getting caught leading to injury Place fingers on the indentations on the sides of the unit and grip it firmly with both hands during installation Precautions Related to Work Oper...

Страница 12: ...circuits Instructions Always use the parts specified in the instruction manual when replacing parts The use of non specified parts may result in them becoming damaged and unusable Measures to be Obser...

Страница 13: ...ad and fully comprehend the details listed in Refer To and implement protective measures without fail Measurement Preparations No Equipment Location Risk Protective Measures Implemented by Users 1 A C...

Страница 14: ...damages attributable to Shimadzu is limited to a sum equivalent to the cost of the product in all cases 4 Warranty Exemption The warranty is not valid for malfunctions attributable to the following e...

Страница 15: ...has elapsed However the supply periods stipulated separately by the manufacturers will be applied for parts not manufactured by Shimadzu Inspections and Maintenance Daily inspections Periodic inspect...

Страница 16: ...Adjusting the Level of the Balance 27 Turning the Power ON 29 Warming Up 29 Performing Span Calibration 30 2 USING THE BALANCE 34 Weighing 34 Outputting Weight Readings 36 Selecting the Display 37 Sw...

Страница 17: ...ustment 52 Perfect Self Calibration PSC ATX R only 56 Calibration of the Internal Weight ATX R Only 58 Leaving a Record of Calibration 61 Example Printout of a Calibration Record 61 Setting Output of...

Страница 18: ...entage Weighing 87 Preparation for Percentage Weighing 87 Weighing Percentages 90 Measuring Specific Gravity of Solids Solid Specific Gravity Measurement 91 Preparation for Solid Specific Gravity Meas...

Страница 19: ...116 Connecting Printers 116 Connecting Personal Computers 117 Connecting PLCs and Other Serial Communications Equipment 119 Cable Connections RS232C 120 Data Format 121 Command Codes 123 Communication...

Страница 20: ...put Function 143 Setting a Balance ID 145 Specifications 146 ATX R ATY R Series 146 Maintenance Parts 147 ATX R ATY R Series 147 List of Functions That Can Be Used in Combination 149 Menu Map 150 Read...

Страница 21: ...surroundings influencing the weight reading Indicates the level of the balance page 27 Windbreak Shows the weighing results information for making function settings the current function setting error...

Страница 22: ...YOUR INFORMATION BEFORE WEIGHING 21 V V Continued on next page Back of the unit RS232C USBDEVISE DC IN connector USB Device Used to connect an AC adapter for power supply Used to connect to a PC P 117...

Страница 23: ...percentage weighing Displays the reference weight In the weighing mode Opens the unit setting menu When piece counting Used to select the item number When performing percentage weighing Used to selec...

Страница 24: ...the upper and lower side is displayed Page 43 Auto print symbol Lit when the auto print function is set Page 111 Communication symbol Indicates that data is being exchanged with an external device Co...

Страница 25: ...ent Or if displayed when the decimal place of the conversion coefficient is changed to an arbitrary setting for each user a value with no decimal point can be input Page 46 Piece counting symbol Lit w...

Страница 26: ...Check that all of the items indicated below are included in the package and that nothing has been damaged The numbers in the boxes indicate the quantity of each item ATX R ATY R Series Balance main bo...

Страница 27: ...alance Note also that if the power supply or voltage is unstable or if the power supply capacity is insufficient it will not be possible to obtain satisfactory performance from the balance Precautions...

Страница 28: ...s dirty easily use the protective cover available 1 Peel off the paper to expose the adhesive on it 2 Fit it on the display 3 Press the adhesive parts firmly to keep fitting it on the display Adjustin...

Страница 29: ...w clockwise If the air bubble is right of center Turn the front left level screw clockwise 3 Turn both the level screws at the front in the same direction at the same time to center the air bubble in...

Страница 30: ...noise will be heard Clamps are attached to the AC adaptor Attach the clamps at an appropriate position as shown in the illustration above Fix the cable of the AC adaptor with clamps on an appropriate...

Страница 31: ...n will start automatically If BUSY is displayed There is something placed on the pan When this item is taken off the pan span calibration will start automatically To cancel scan calibration press If E...

Страница 32: ...alance be sure to turn the power on and start it up correctly so that the internal weight is correctly held ATY R Series 1 Press The weight value will flash If WAIT is displayed The calibration record...

Страница 33: ...age 45 For details on the weight values that can be entered see Specifications page 146 3 Place the calibration weight on the pan Open the glass door in the windbreak place the weight on the pan and s...

Страница 34: ...on weight off the pan Open the glass door in the windbreak remove the weight from the pan and shut the glass door again After a while END will be displayed and the balance will return to the weighing...

Страница 35: ...it or ready symbol lit Press any key The application function mode is established Press for about 3 seconds A menu indication is displayed Press a number of times Or press for about 3 seconds The bala...

Страница 36: ...Check that the glass door is fully shut before reading the balance display Avoid doing the following Putting your hand inside the glass door of the windbreak Touching the container or sample with bare...

Страница 37: ...When the GLP output function page 143 is set to OFF only the weight reading is output When the GLP output function page 143 is set to ON the following information is output Outputting Weight Readings...

Страница 38: ...Selecting Units to Display page 78 When user specified units have been selected the characters and symbols that indicate the units don t light up Unit display after restarting When the power is turne...

Страница 39: ...IN 3 Select switching between 1D and 10D and confirm at 10D 1D 10D 4 Return to the weighing mode or Display after selection The decimal place doesn t change Note also that when one digit is removed th...

Страница 40: ...10D display in step 4 Selecting the Decimal Point Display Symbol The decimal point can be displayed as either a period or a comma 1 Press twice shortly in the weighing mode This opens the main menu 2...

Страница 41: ...or The way the decimal is displayed has now changed Selecting the decimal point display symbol When the decimal point display is changed the decimal point changes accordingly in data output to externa...

Страница 42: ...mpletely disconnect the AC adapter What is the standby mode This is the status in which the balance stands by saving electricity although it can still be used right away On pressing in the weighing mo...

Страница 43: ...r Unit setting menu Used to set which units may be displayed in weighing mode You can open each menu group by pressing the various operation keys Press and hold for about 3 seconds Unit setting menu P...

Страница 44: ...or a number of times to search for the next menu option Press to confirm Press to proceed to the next menu option User operations Flow of menu operations Press a number of times Information displayed...

Страница 45: ...nu display 2 Confirm and return to the weighing mode The operation after confirming the menu selection differs depending on the menu and you will either be returned to the weighing mode automatically...

Страница 46: ...hifts the decimal point to the left Decreases the value of the digit to be entered the flashing digit Pressing this key while the decimal point is flashing shifts the decimal point to the right Shifts...

Страница 47: ...dure for shifting the position of the decimal point one digit to the left to change the displayed value from 100 000 to 10 0000 1 Establish the numeric value entry mode the number symbol lights and th...

Страница 48: ...page 150 and on the menu map sheet 1 Press twice shortly in the weighing mode This opens the main menu 2 Select menu reset TOOLS SYSTEM RESET OK 3 Enter the password The password is set to 9999 befor...

Страница 49: ...about three seconds while OFF is displayed after supplying power or while in the standby mode 2 Enter the password Entering Numerical Values page 45 3 Press The password will be accepted The menu wil...

Страница 50: ...option 10 CONNECTION AND COMMUNICATION WITH PERIPHERAL DEVICES page 111 2 Press twice shortly in the weighing mode This opens the main menu 3 Select output of menu setting information TOOLS SYSTEM CO...

Страница 51: ...y is corrected Registering the internal weight ATX R only or the external weight on you can start operations only by pressing The operation to calibrate the internal weight itself cannot be registered...

Страница 52: ...NTLY 51 3 Confirm and return to the weighing mode SET or Whichever was selected in step 2 is set for and the balance returns to the weighing mode When executing span calibration see Span Calibration a...

Страница 53: ...page 143 has been set to ON initially the indication WAIT is displayed then the balance model name and other information is output After a little while the weight symbol lights up and span calibratio...

Страница 54: ...a discrepancy in the value of the internal weight Press and redo the operation from the beginning If even on doing this the same display reappears calibrate the internal weight page 58 END will be dis...

Страница 55: ...bration will start automatically If BUSY is displayed There is something placed on the pan Take the item off the pan and follow the procedure below To cancel scan calibration press If no operation is...

Страница 56: ...in the windbreak remove the weight from the pan and shut the glass door again END will be displayed and the balance will return to the weighing mode Avoid doing the following Putting your hand inside...

Страница 57: ...s any load on the pan or not Case1 There is no load on the pan PSC RUN is displayed and automatic span adjustment is executed It returns to the weighing mode when automatic span adjustment ends To con...

Страница 58: ...ing Off OFF Default setting Displayed ON 4 Press the several times or press and hold the for 3 seconds to return to mass measurement mode In the case of a verified balance as a legal measuring instrum...

Страница 59: ...weight P CAL 3 Enter the administrator s password Entering Numerical Values page 45 Changing the Password page 142 If the password is wrong The error message shown to the right will be displayed and t...

Страница 60: ...can be used refer to Specifications page 146 6 Place the weight on the pan Open the windbreak glass door place the calibration weight on the pan and close the glass door again Wait until the flashing...

Страница 61: ...tainer has been placed on the pan The pan is not on the balance There is too large a discrepancy in the value of the internal weight Press and repeat the operation from the beginning END is displayed...

Страница 62: ...output calibration record includes the following items D ATX224R 200 0000g 200 0001g 200 0000g Example printout from printer When the GLP output function is set to ON Weight used Balance weight readi...

Страница 63: ...istic calculation function of the printer cannot be used 1 Press for about 3 seconds This opens the calibration menu 2 Select the GLP output function GLP OUT Stability Mark GLP Output Function Lit ON...

Страница 64: ...gement number ID for each balance which will be indicated as part of calibration records output 1 Press twice in the weighing mode This opens the main menu 2 Select setting of a balance ID TOOLS SYSTE...

Страница 65: ...on the pan after measurement is automatically compensated for See Hint as blow page 66 Auto tare function After outputting a weight reading taring is executed automatically page 68 Zero tare timing c...

Страница 66: ...ction Lit ON Unlit OFF If you proceed to the next step while zero tracking is ON it goes OFF 2 Press twice This opens the main menu Setting from the zero taring menu You can also press for about 3 sec...

Страница 67: ...ou want to do Stability Mark Auto Zero Function To set or Update To Cancel Lit ID is ON Press and go to step 3 Press and go to step 4 Unlit ID is OFF Press and go to step 3 Go to step 4 3 Enter the va...

Страница 68: ...ected change update the setting for the zero range value by following the procedure from step 1 while these new units are displayed The upper limit value for the zero range is 99 d 1 d is the minimum...

Страница 69: ...about 3 seconds in the weighing mode This opens the zero taring menu 2 Select the auto tare function A TARE Stability Mark Auto Tare Function Lit ON Unlit OFF 3 Change the setting Pressing alternately...

Страница 70: ...e stability mark to light up Not applicable to a verified balance as a legal measuring instrument 1 Press for about 3 seconds in the weighing mode This opens the zero taring menu 2 Select the zero tar...

Страница 71: ...mart setting function on By pressing and you can adjust stability and response Easy Setting of Response and Stability page 72 Adjusting the stability mark The conditions for making the stability mark...

Страница 72: ...ighing mode This opens the main menu 2 Select the general weighing mode STAND SET The balance has been set in the general weighing mode Selecting the Pouring Mode This is the weighing mode suited to p...

Страница 73: ...the other Easy Setting allows quick adjustment to match your preference requirements or particular application 0 0 0 0 0 Easy setting indicator Pressing in the weighing mode flashes the smart setting...

Страница 74: ...ess this key the further the level indicator moves to the S side increasing the stability of the display in stages When you want to weigh things quickly When you want to improve working efficiency Whe...

Страница 75: ...change while the stability mark remains lit or the stability mark may light temporarily and then the weight reading may change Setting the Stability Detection Range The stability detection range is a...

Страница 76: ...according to which the stability mark lights can be set in accordance with the application and required accuracy Not applicable to a verified balance as a legal measuring instrument Effect of speeding...

Страница 77: ...B MK 3 Check the lighting timing setting FAST Stability Mark Stability Mark Lighting Timing Lit Fast Unlit Standard 4 Change the stability mark lighting timing Pressing alternately sets the fast and s...

Страница 78: ...ligram 0 001 1000 ct carat 3 0 2 5 mom momme 6 3 75 0 2666667 User 4 5 Can be set as required by the user 4 1 If we take the value in the Gram conversion column to be a the formula is as follows a bal...

Страница 79: ...o be called up and check if the stability mark is displayed or not Select the units Stability Mark Registering Units Lit ON Unlit OFF 3 Change the setting for units Pressing alternately sets the ON an...

Страница 80: ...rent situation What do you want to do Stability Mark User Specified Units To Set Update To Cancel Lit Set Press and go to step 3 Press and go to step 5 Unlit Cancelled and go to step 3 Go to step 5 3...

Страница 81: ...nits Make the setting by replacing steps 3 and 4 of the conversion factor procedure page 79 with the following procedure 3 Select setting of the minimum indication MIN D 4 Enter the minimum indication...

Страница 82: ...mode is set Pressing for 3 seconds alternately selects the weighing mode gram or other unit indication and the application function mode in use It can be used in combination with the comparator funct...

Страница 83: ...inimize the counting error In step 5 of Preparation for Piece Counting make the number of pieces used for setting the unit weight as large as possible When actually measuring numbers of pieces don t p...

Страница 84: ...ate the unit weight proceed to step 5 If you are not intending to update the unit weight the procedure from step 5 on is unnecessary You can start piece counting right away Counting Numbers of Pieces...

Страница 85: ...7 Put a quantity of the item to be counted corresponding to the selected number of pieces used for setting into the container 8 Check that the stability mark lights up then confirm SET The unit weight...

Страница 86: ...splayed If the display appears as shown to the right This means that the unit weight has not been set for the selected item number To make this setting follow the procedure in Changing a Unit Weight o...

Страница 87: ...you press for about 3 seconds the next item number is displayed Counting Numbers of Pieces page 85 3 Place the container on the pan and press The balance will be tared 4 Press twice The number of pie...

Страница 88: ...he reference weight is set as a percentage value of your choice Preparation for Percentage Weighing 1 Press twice in the weighing mode This opens the main menu 2 Select percentage weighing APL FUNC PE...

Страница 89: ...age reference value the following steps are not necessary Weighing Percentages page 90 4 Place the container on the pan and press The balance will be tared 5 Select 100 reference setting Press twice 1...

Страница 90: ...d to step 4 If you are not updating the percentage reference value the following steps are not necessary Weighing Percentages page 90 4 Place the container on the pan and press The balance will be tar...

Страница 91: ...The balance will be tared 3 Insert the sample item to be measured into the container A percentage value obtained by conversion based on the set reference percentage value and reference weight is displ...

Страница 92: ...s when using the kit Preparation for Solid Specific Gravity Measurement 1 Press 2 times in mass measurement mode The main menu will open 2 Select specific gravity measurement APL FUNC SG SET 3 Select...

Страница 93: ...ium for the input temperature will be automatically displayed for 3 seconds and then the device will switch to specific gravity measurement mode When the medium is set to OTHER the device will switch...

Страница 94: ...tion can be set to maintain the currently displayed specific gravity value while is pressed making it easier to read the value Configuration method 1 Press 2 times in mass measurement mode The main me...

Страница 95: ...sured in air Mass of sample measured in liquid Density of liquid used normally water Formula which does include air buoyancy correction Mass of sample measured in air Mass of sample measured in liquid...

Страница 96: ...de The main menu will open 2 Select specific gravity measurement APL FUNC SG SET 3 Press the or several times to display AIR COR 4 The stability mark will be displayed or turned off each time the is p...

Страница 97: ...in air will be displayed 4 Wait until the stability mark is displayed then press and SINK will be displayed as shown in the image to the right 5 Next place the sample on the underwater weighing pan th...

Страница 98: ...ater Do not use ethanol if the solid sample will be affected by or react with ethanol It is necessary to strictly abide by all safety related regulations when handling ethanol Method 2 Measurement usi...

Страница 99: ...asurement kit allows for easier measurement of specific gravity Refer to the kit instruction manual for usage methods Glass Sinker Volume Measurement If the volume of the glass sinker is not known the...

Страница 100: ...ratures Temperature C Density g cm3 Temperature C Density g cm3 Temperature C Density g cm3 10 0 9997 19 0 9984 28 0 9963 11 0 9996 20 0 9982 29 0 9960 12 0 9995 21 0 9980 30 0 9957 13 0 9994 22 0 997...

Страница 101: ...be changed as described below Increase value Decrease value Move right Confirm value The symbol indicates the balance is in value input mode The first digit from the right will blink and can be chang...

Страница 102: ...Lower the sinker and the sinker s weight in air will be displayed 4 Wait until the stability mark is displayed then press and SINK will be displayed as shown in the image to the right 5 Install the w...

Страница 103: ...mulation 1 Press twice in the weighing mode This opens the main menu 2 Set the balance to the formulation mode APL FUNC FORMULA SET The balance is now ready to weigh If necessary set output of the com...

Страница 104: ...the operations in steps 5 and 6 to add the other components to the formulation 7 On completion of formulation press The total of the individual weight values up to this point gross weight is displayed...

Страница 105: ...tatus When weighing is in progress On long pressing The gross weight of the components weighed up to that point is displayed for about 2 seconds Example printout from printer When the GLP output funct...

Страница 106: ...blished Perform steps 1 and 2 of formulation page 102 2 Select component number output setting ELM NUM Stability Mark Outputting Component Numbers Lit ON Unlit OFF 3 Change the output setting Pressing...

Страница 107: ...s the main menu If the ready to weigh status is not established Perform steps 1 and 2 of formulation page 102 2 Select gross weight output setting TOTAL Stability Mark Outputting the Gross Weight Lit...

Страница 108: ...ator Function You can select and use either of these modes according to the environment of use and application Target mode After setting a target value and a tolerance range with respect to that targe...

Страница 109: ...sample into the container Excess or deficiency is determined according to the the following conditions Condition Judgment Comparator Symbol Over the target value range Large difference with respect t...

Страница 110: ...Press and go to step 3 Press and go to step 4 Unlit OFF Press and go to step 3 Go to step 4 3 Enter the pass range upper limit value and lower limit value and the checkweighing range lower limit valu...

Страница 111: ...ting 4 Return to the weighing mode or 5 Place the container on the pan and press The balance will be tared 6 Insert the sample item to be measured into the container Pass or fail determination is base...

Страница 112: ...ed weight reading at each weighing without pressing Select the output timing from among the following five modes Stable Positive Value Stable Negative Value Stable Zero Indication Pass in Checkweighin...

Страница 113: ...Z RET RET 0 or RET 50 SET What is zero return requirement After the previous sample item to be weighed has been removed from the pan the weight reading must fall below the zero value and stability mu...

Страница 114: ...weight reading is automatically output Printing Outputting Continuously Continuous Output Function This function allows displayed weight readings to be automatically output continuously in the same ti...

Страница 115: ...ther starting of the continuous output is performed manually by key operation MANU Pressing alternately sets the ON and OFF settings SET 5 Set whether the non averaged value is output as a continuous...

Страница 116: ...esh cycle approximately 100 msec intervals Pausing and restarting the continuous output function To pause the function press To restart it press When OFF is set for MANU in step 4 MANU is set to ON wh...

Страница 117: ...values setting statuses and other data Connect the printer to the balance in accordance with the following procedures 1 Switch off the power to the balance and the printer 2 Firmly connect the cable...

Страница 118: ...the PC and the USB DEVICE connector on the rear of the balance 3 Switch on the power to the balance 4 The USB driver will be automatically installed on the PC If the USB driver does not install correc...

Страница 119: ...ications are to be performed with communication software installed onto the personal computer make sure the settings are made in accordance with the instructions for that software 6 Decompress the dow...

Страница 120: ...tion with special commands and read and write setting values Connect the equipment to the balance in accordance with the following procedures in this event 1 Switch off the power to the balance and ot...

Страница 121: ...or the relevant equipment first of all and then check operations in accordance with the following procedures 1 Check the cable connection 2 Check that the communication conditions are in alignment 3 E...

Страница 122: ...iter and so on Data length for this example 12 bytes 1 2 3 4 Position 1 2 3 4 5 6 7 8 9 10 11 12 ASCII code 2DH 31H 32H 33H 2EH 34H 35H 36H 37H 67H 20H 0DH Data 1 2 3 4 5 6 7 g C R No Position Explana...

Страница 123: ...e is added after position 12 in the standard format Accordingly the data length is increased by one byte When there is OL or OL overload output The data format when OL is included is shown below Data...

Страница 124: ...end Example 2 ID 1 2 3 4 C R This sets 1234 as the balance ID Example 3 UW1 1 2 3 C R Example for models with two places after the decimal point This sets 1 23 g as the unit weight for piece counting...

Страница 125: ...Only use upper case letters of the alphabet numerals and some symbols including the decimal point and signs and limit the string to within 15 characters Command list Data output Command Function D01...

Страница 126: ...nctions Command Function Comparator TRGT Establishes the target mode TARGET XX XXXX Sets the target in the target mode XX XXXX Setting value LIMIT XX XXXX Sets the target range in the target mode CHKW...

Страница 127: ...g Sets gram units mg Sets milligram units only accepted by models capable of displaying 0 001 g ct Sets carat units mom 1 Sets momme units Other companies commands Command Function TI Immediate tarin...

Страница 128: ...pecified settings MODE 1 MODE 2 MODE 3 MODE 4 MODE 5 MODE U Relevant manufacturer Shimadzu standard Shimadzu responses given Mettler Sartorius A D Baud rate communication speed 1200 1200 2400 1200 240...

Страница 129: ...s the output menu 2 Select communication setting COMM SET Select the mode SET 3 Return to the weighing mode or User Specified Settings In this setting each of the communication settings can be set acc...

Страница 130: ...ate 300 bps 600 bps 1200 bps 2400 bps 4800 bps 9600 bps 19 2k bps 38 4k bps Setting the parity bit length PARITY Select the parity SET Indication pP NONE ppP ODD ppP EVEN Parity bit length No parity 8...

Страница 131: ...ormat 1 function This is the same format as used by Mettler balances S This is the same format as used by Sartorius balances This is a format that allows the leading bytes and number of send data to b...

Страница 132: ...ress for about 3 seconds in the weighing mode This opens the output menu 2 Select the output timing change function APL PRN PRINT F Stability Mark Output Timing Change Function Lit When immediate outp...

Страница 133: ...ch the shaft and not to allow dusts come inside from holes around the shaft Main body Avoid using organic solvents chemical agents or cloths impregnated with chemicals since they will damage the coati...

Страница 134: ...hands on the door rail Exercise due care when handling broken glass 1 Remove the pan ring the pan and pan supporter 2 Turn the knob on the inner side of the handle to remove the handle Caution Prohib...

Страница 135: ...cessary Here are some examples for your reference Daily Inspection Reference Example 1 Daily Inspection Reference Example 2 Frequency of inspection Once per day Once to several times per day as requir...

Страница 136: ...eatability Weigh a weight that corresponds to approximately half of the weighing capacity of the balance five to ten times and assess the dispersion in the weight readings obtained Eccentric error Ass...

Страница 137: ...cting the class of weight As the main form of classification weights are normally divided into classes according to their degree of accuracy Select the most appropriate class of weights to be used for...

Страница 138: ...elow shows the recommended calibration weights to be used for balances with different weighing capacities Weighing Capacity of Balance Recommended Weight of Weight for Calibration 62 g 60 g 50g 10g 82...

Страница 139: ...e pan z z Place the object so it does not sticks out too much of the pan z z Check if anything other than the object for weighing touches the pan z z Avoid anything other than the object for weighing...

Страница 140: ...he correct numerical value Page 45 ERR W Operation error z z The operation used is wrong z z After the error is displayed the balance returns to the status immediately before the error occurred At thi...

Страница 141: ...n What do you want to do Stability Mark Auto Power Off Function To Set Update To Cancel Lit ON Press and go to step 3 Press and go to step 4 Unlit OFF Press and go to step 3 Go to step 4 3 Enter the t...

Страница 142: ...lit display and then to he weighing mode All segments lit After the power is turned on the balance stops with the OFF display When any of the keys is pressed during the OFF display the balance stops...

Страница 143: ...s the main menu 2 Select the password TOOLS SYSTEM PASS WRD 3 Enter the current password Enter the current password 4 Enter the new password OK Enter the current password Entering Numerical Values pag...

Страница 144: ...printer cannot be used Example printout from printer When the GLP output function is set to ON SHIMADZU CORP D 200 0000g ATX224R Balance model name Weight reading The person who carried out measuremen...

Страница 145: ...ditions below Handshake Settings in the Communication Settings page 129 Rough Time Required for Output of One Weight Reading Printer Only PC Only Both Printer and PC used OFF Approx 10 sec Approx 3 se...

Страница 146: ...rning the GLP output function ON you can add the balance ID to calibration records page 61 and weight reading outputs 1 Press twice in the weighing mode This opens the main menu 2 Select setting of a...

Страница 147: ...nt for sensitivity 10 30 C 2 ppm C Pan size mm Approx f 91 3 Main body dimensions mm Approx 213 W 356 D 338 H Main body weight ATX R approx 6 2 kg ATY R approx 6 0 kg Display LCD Rated electric power...

Страница 148: ...2 Pan supporter S321 71284 With 4 rubber parts Pan ring S321 71053 01 AC adaptor Contact your distributor Horizontal adjustment stands S321 71069 01 Glass door left ASSY S321 71043 01 Glass door right...

Страница 149: ...900 12 Printer EP 110 for Eurpe S321 73900 36 Please use this model for legal measuring in Europe The following label is attached to this model Protective Cover 5 pcs S321 71026 STABLO AP S321 73700 0...

Страница 150: ...g Mode Continuous Output Auto Print Output Timing Change Function GLP output function Application Function Mode Piece Counting Percentage Weighing Specific gravity measurement Formulation Comparator T...

Страница 151: ...ization of the menu settings and the method of operation of the menu see 3 MENU SETTINGS page 42 Reading the Menu Map Conventions Used in the Menu Map Explanation of Operation Press or to search for t...

Страница 152: ...P 102 P 107 P 109 TOOLS Other functions TARGT Target mode CHECK W Checkweighing mode PARAM W Weighing parameters SYSTEM System START Start display AUTO OFF Auto power off HI LIM Pass range upper limit...

Страница 153: ...Menu Map 13 FOR YOUR INFORMATION P 63 P 142 P 49 P 47 RESET Menu reset COND OUT Menu settings output PASS WRD Password BAL ID Balance ID 1 Not applicable to a verified balance as a legal measuring ins...

Страница 154: ...tings AUTO PRN Auto print function APL PRN Application output LD UL On Ld LD UL Z On 0Ld LD OK On OK LD On Ld LD Z On 0Ld Z RET Zero return judgment SEQ PRN Continuous output function NO FIL No filter...

Страница 155: ...mode P 143 P 58 GLP OUT GLP output function Calibration of the internal weight ATX R series only I CAL P 52 P CAL Span calibration using the internal weight CAL EXE Calibration E CAL P 54 Span calibra...

Страница 156: ...102 G General weighing mode 71 Glass door 132 GLP output function 62 143 Gram 77 Gross weight 23 Symbol OL 139 Number 100 reference 87 Alphabets A Adjusting the level 27 All segments lit 141 Applicat...

Страница 157: ...24 90 Perfect Self Calibration 56 Perfect Self Calibration symbol 23 Periodic inspections 135 Piece counting mode 85 Piece counting symbol 24 85 Position of the decimal point 46 Pouring mode 71 Pouri...

Страница 158: ...esponse 70 RS232C connector 21 S Selecting units to display 78 Span calibration 52 Specific percentage reference 87 Specific percentage weighing symbol 24 89 Stability 70 Stability detection range 74...

Страница 159: ...158 MEMO...

Страница 160: ...rt Hahn Strasse 6 10 47269 Duisburg F R Germany Phone 49 203 7687 0 Fax 49 203 7666 25 SHIMADZU HONG KONG LIMITED Suite 1028 Ocean Center Harbour City Tsim Sha Tsui Kowloon HONG KONG Phone 852 2375 49...

Отзывы: