SD16A Instruction Manual 

 

6. Instruction for each screen 

 

6-1. Screen sequences

 

 

 

1-4

1-1

0-0

1-0

1-17

1-18

1-19

1-20

1-21

1-22

1-23

1-24

1-2

1-3

1-5

1-6

1-7

1-8

1-9

1-10

1-11

1-12

1-13

1-14

1-15

1-16

0-1

0-2

0-3

0-4

0-5

0-6

0-0

1-0

to

Basic screen

to

1-0 screen

Basic screen

Model name

Input type

Measuring range

lower-limit value

Measuring range

higher-limit value

PV filter

Alarm 2

latching release

Alarm 1

latching release

Alarm 1

setting value

Alarm 2

setting value

PV bias

lower-limit value

higher-limit value

Communication

mode

Communication

protocol

Communication

address

Communication

data format

Communication

speed

Communication

delay

Communication

start character

Communication

BCC operation

Alarm 1

code

Alarm 1

hysterisis

Alarm 1

inhibit

Alarm 2

code

Alarm 2

hysterisis

Alarm 2

inhibit

Mode 0

Screen Group

Mode 1

Screen Group

Power ON

Screen Group

For approx. two secs

Key lock

Display

update cycle

Measuring range

Decimal places

Input unit

decimal places

Screens always displayed.

Screens displayed or not displayed

depending on some conditions.

Screens displayed when any option is added.

Each screen is classified by the screen frame as follows.

Key operations on screens of Power ON Screen Group

No key operation is required as screens alter automatically
within Power ON Screen Group.

Key operations on screens of Mode 0 Screen Group

Mode 0 Screen Group consists of screens that are often used under

control operation. The commonly-used key operations are as follows:

   Shifting a display screen to the next display screen

   Shifting a display screen to the setting screen

   Returning from a setting screen to the display screen

   Shifting from 0-0 screen to 1-0 screen

approx. 2 secs.

Key operations on screens of Mode 1 Screen Group

Mode 1 Screen Group consists of screens that are used less often

than Mode 0 screens, and are required according to the input type or

controllability. The commonly-used key operations are as follows:

   Shifting a display screen to the next display screen

   Shifting a display screen to the setting screen

   Returning from a setting screen to the display screen

   Returning from any display screen of Mode 1

   to 1-0 screen

   Returning from 1-0 screen to 0-0 screen

Auto return feature

If no key operation is executed on any screen but the Basic screen

(0-0) for three minutes or more, the screen returns to

the Basic screen automatically.

 approx. 2 secs.

or

4

 

 

Содержание SD16A Series

Страница 1: ...injury due to electric shock CAUTION To avoid damage to the connected equipment facilities or the product itself due to a fault of the product safety countermeasure must be taken before usage such as...

Страница 2: ...2 Notes for use Avoid operating the front panel keys with hard or sharp objects Lightly touch the operating keys with your fingertips for operation When cleaning do not use a solvent such as a thinner...

Страница 3: ...st digit of the decimal point blinks until this registration by pressing the Entry key Shifts between a display screen and the setting screen In this case the light of the last digit of decimal point...

Страница 4: ...n is added Each screen is classified by the screen frame as follows Key operations on screens of Power ON Screen Group No key operation is required as screens alter automatically within Power ON Scree...

Страница 5: ...sic screen 0 0 KEEP RSET KEEP 0 3 PV bias The PV bias value is displayed or can be set The value is used for compensating input errors by the sensor etc When the value is set the compensated PV is dis...

Страница 6: ...he eset values are initialized However L The Alarm 2 action type is displayed or can be set As for action types refer to Ac Alarm o HA_L Higher limit absolute value with latching LA_L Lower limit abso...

Страница 7: ...f alarm optionally Action type The f rm output action types scree supported he lower limit absolute value alarm ollowing ala n 1 9 or 1 12 are T The higher limit absolute value alarm Scale over The la...

Страница 8: ...0V AC 1 5A resistive load Output update cycle 0 25 secs Isolation Isolated between alarm output and input between alarm output and analog output sensor power supply between alarm output and communicat...

Отзывы: