CONTENTS

Page

1. Introduction

............................................................................ 3

1-1. Check before use ............................................................. 3

1-2. Caution for use ................................................................ 3

2. Installation and wiring

 .......................................................... 3

2-1. Installation site (environmental conditions) .................... 3

2-2. Mounting ......................................................................... 3

2-3. External dimensions and panel cutout ............................. 4

2-4. Wiring.............................................................................. 4

2-5. Terminal arrangement...................................................... 4

2-6. Terminal arrangement table ............................................. 4

3. Instruction for front panel

..................................................... 4

3-1. Front illustration and the name of parts ........................... 4

3-2. Instruction for front panel................................................ 4

4. Explanation of each screen

.................................................... 5

4-1. List of screen sequence.................................................... 5

4-2. Mode 0 screen group ....................................................... 6

4-3. Mode 1 screen group ....................................................... 6

4-4. Table of measuring range code ........................................ 7

4-5. Table of alarm type code ................................................. 7

4-6. Method of shifting screens .............................................. 7

5. Supplementary explanation

................................................... 7

5-1. Display update cycle (Screen No.1-2) ............................. 7

5-2. Alarm output action (option) ........................................... 7

5-3. Analog output action (option) ......................................... 7

5-4. Auto-return function........................................................ 7

6. Error message

......................................................................... 7

7. Specification

 ........................................................................... 8

1. Introduction

1-1. Check before use

The instrument passes thorough quality checks before shipment.

When the instrument is delivered, please confirm the type code

number, then check the external conditions and the list of

accessories.    Make sure that there are no apparent damages or

discrepancies.

Confirmation of the type code: Collate the type code printed on the

label attached to the packing case with the following schema and

confirm that the delivered goods meet your order.

SD16- 8    90-    0    0    0    0

Item

Reference code and contents

1. Series

SD16 : 48 

×

 96 DIN size    Digital Indicator

2. Input

8: 

Multi-input, 

thermocouple, 

R.T.D.,

Voltage (mV, V), Current (mA)

3. Power supply

90-: 100   240V AC 

±

10% (50/60Hz)

08-: 24V AC (50/60Hz)/DC 

±

10%

4. Alarm (option)

0: None

1: Alarm output

5. Analog output (option)

0: None

3: 0~10mV DC (output resistance 10 )

4: 4~20mA DC (load resistance 300  max.)

6: 0~10V DC (load current 1mA max.)

6. Communication (option)

0: None

5: RS-485

7: RS-232C

7. Remarks    0: Without    9: With

Accessory list check:

Instruction Manual 

1 copy

Unit decal

1 sheet

Communication Instruction Manual

1 copy

(In case of optional communication selected)

Note:

Contact our representative concerning any problems

with the product, accessories or related items.

1-2. Caution for use

(1) Avoid operating keys of the front panel with hard or sharp

objects or motions.    Lightly touch the operating keys with

finger tip for operation.

(2) When cleaning, do not use solvent like thinner.    Wipe the

instrument with dry cloth lightly.

2. Installation and wiring

2-1. Installation site (environmental conditions)

Do not install the instrument at a place of environmental

conditions as listed below.    Otherwise, it will cause damages

to the instrument and may even result in fire.

(1) Where flammable or corrosive gas, oil soot or dust that

deteriorates insulation is generated or abundant.

(2) Where ambient temperature is below 

10

°

C or above 50

°

C.

(3) Where ambient humidity is higher than 90% RH, or below dew

point.

(4) Where strong vibrations or impact is generated or transferred.

(5) Where there is a high-tension electrical circuit in the

neighborhood, or induction interference.

(6) Where under exposure to direct sun light or dew drops.

(7)

 

Where the elevation is higher than 2000m.

(8)

 

Outdoors

Note:

The environmental conditions belong to the installation

category II of IEC 664 and the degree of pollution is 2.

2-2. Mounting

(1) Cut a fitting hole by referring to the panel cutout plan in item

2-3.

(2) Applicable thickness of the panel is 1.0 ~ 4.0mm.

(3) The instrument has catching claws to fix it in position.      

Just push it in from the front panel.

Note:

SD16 is a panel installation type indicator.    When the

instrument is used, make sure to mount it on a panel.

CAUTION

Содержание SD16 series

Страница 1: ...es Please check that the delivered product is the correct item you ordered Please do not begin operating this product until you have read this instruction manual thoroughly and understand its contents...

Страница 2: ...alled adjacent to the instrument at a position which allows easy access of the operator Put up a sign indicating that this switch is for shutting down the power of the instrument Regarding the fuse Si...

Страница 3: ...d resistance 300 max 6 0 10V DC load current 1mA max 6 Communication option 0 None 5 RS 485 7 RS 232C 7 Remarks 0 Without 9 With Accessory list check Instruction Manual 1 copy Unit decal 1 sheet Commu...

Страница 4: ...T D B thermocouple voltage mV V current R T D B 5 6 7 9 Alarm output option terminal COM contact point rating 240V AC 1 5A load resistance AL1 AL2 11 12 13 Communication option terminal SG SG SD RD 15...

Страница 5: ...5 4 Explanation of each screen 4 1 List of screen sequence Alarm...

Страница 6: ...Initial value 5 unit Setting range 1 999 unit This screen is for setting Alarm 1 hysterisis In case of the system without alarm option this screen is not displayed Alarm 2 code Initial value LL__ Sele...

Страница 7: ...is set with a difference less than 10 counts from that of the higher limit value the lower limit value is forcibly changed to a new value at higher limit value plus 10 counts As a result when the lowe...

Страница 8: ...ut filter Isolation Between input and analog output Alarm output option Number of alarm points 2 AL1 and AL2 for both normal open and common Alarm type Selectable from combinations of the following 4...

Отзывы: