Basic Part

Thank you for purchasing our product. Please check that the delivered product is
the item exactly as ordered by you. Please read this manual thoroughly to
understand the contents before you start operating the product.

Please ensure that this instruction manual is given to the end user.
For details of the operation and parameters of Shimaden instruments to be connected to the
GAT10-DN, please refer to the instruction manual and communication interface instruction
manual of the instrument.

This instruction manual is meant for persons involved in wiring, installation, operation and
routine maintenance for the GAT10-DN. It describes matters to be attended to in handling
it, how to install it, wiring for it, its functions and operating procedure. It is requested that
for ready reference, this manual is kept at the work site where the GAT10-DN is used.
In operating it, please follow the instructions contained herein.

This instruction manual describes matters to be attended to concerning safety, potential damage
to equipment and/or facilities, additional explanations and notes under the following headings:

"

Warning"

This heading indicates that failure to follow instructions could cause injury or
even death.

"

Caution"

This heading indicates that failure to follow instructions could cause damage
to equipment and/or facilities.

"Note"

This heading indicates additional explanations or notes.

The safety rules apply only to this product. For those as a PLC system, please refer to the User's
Manual of PLC Unit.

The GAT10-DN is designed for general industrial use. Therefore, it should not be used in any
way that might result in injury or fatality, or must be used only after adequate safety measures
are taken. No responsibility will be taken for any accident resulting from the usage of this
product without appropriate safety measures being in place.

The GAT10-DN must be housed in a control box or the like to prevent the terminal board
from coming into accidental physical contact with personnel.

The GAT10-DN should not be taken out of the case. If your hand or an electric conductor is
put inside it, an electric shock may result in serious injury or even death.

Make sure that the protective conductor terminal is grounded.

If there is any possibility of doing harm or damage to peripheral devices, equipment or
products, you must take appropriate safety measures such as installing the proper fuse or an
overheating prevention device before you start using the GAT10-DN. No responsibility will be
taken for any accident resulting from the usage of this product without appropriate safety
measures being in place.

As means to turn the power off, a switch or a breaker should be installed in the external
power circuit to be connected to the power supply terminal of the GAT10-DN. The switch
or the breaker should be installed adjacently to the GAT10-DN and in a position which
allows it to be operated easily, with an indication that it is a means of disconnecting the
GAT10-DN from its power source. The switch or the breaker should meet the GAT10-DN
requirements of IEC60947.

Fuse:
The instrument has no built-in fuse. Ensure to install a fuse in the power circuit to be
connected to the power supply terminal. The fuse should be placed between the GAT10-DN
and the switch or the breaker.
Fuse Rating/Characteristic: 250VAC 0.5A/ In the case of a medium time-lagged or time-
lagged type switch, one which meets the requirements of IEC60127 should be used.

Make sure that a draft hole should not be blocked and that it should be protected from dust
and dirt. Failure to do so might cause fire or faulty operations.

Do not repeat endurance tests for voltage, noise, surging and the like. Doing so might cause
fire or faulty operation.

Do not attempt to disassemble, repair, or modify the GAT10-DN. Doing so might cause fire
or faulty operation.

1. Safety Rules

Caution

Control lines and communication cables should not be bundled with the main power circuit
or the power line, or installed adjacently. They should be spaced apart by more than 100 mm
as a guideline. Failure to do so might cause faulty operation.

This instruction manual: 1

Connector

: 1

Mounting base

: 1

 Note: If you find a problem with the product or some of the attached items missing, please

contact our sales agent.

Checking Attached Items

Avoid installing the GAT10-DN in the following locations. Failure to do so might cause fire or
faulty operations.

Where flaming gas, corrosive gas, soot, or particles that can deteriorate electrical insulation
is generated or is abundant.

Where ambient temperature lowers below -10

 or exceeds 50

.

Where relative humidity exceeds 90%RH or falls below dew point.

Where highly intense vibration or impact is generated.

Near high voltage power lines or where inductive interference can affect the operation of
the product.

Where the product is exposed to direct sunlight, wind or rain.

Where the elevation exceeds 2,000 m.

Where the product is directly exposed to the flow of emitted air.

Installation Site

Caution

In wiring, close attention should be paid to the following.

Always disconnect the GAT10-DN from any power source during wiring operation to
prevent an electric shock.

Make sure that the protective conductor terminal

is grounded properly. Failure to do so

might cause electric shock.

Don't touch the wired terminals and charged devices while the instrument is energized.
Doing so might cause electric shock.

Wiring

Caution

External Dimensions

This is the "Basic" Part of the instruction manual. Please also read the "Design" Part,

 which

you can download from our website

.

 (URL http://www.shimaden.co.jp)

The GAT10-DN enables writing and reading, from the DeviceNet, of Measured values,
Target set values and parameters for up to 8 Shimaden instruments with RS-485
communication.

The GAT10-DN is connectable to the following Shimaden products:
Digital controllers : SR80 series, SR90 series, SR253
Program controller: FP93
Digital indicator : SD16
Servo controller

: EM70

3. Specifications

Item

Supply voltage

General Specifications

Power consumption

Insulation resistance

Dielectric strength

Mounting
Mass

Temperature
Humidity

Storage temperature

Approx. 250g

Including base

DIN rail or screw

Specifications

100

240V AC

±

10% 50/60Hz

24V AC

±

10% 50/60Hz

24V DC

±

10%

-10

50

90%RH or less

no dew condensation

2. Preliminary Steps

Please confirm that the delivered product is exactly as you specified by comparing the
model codes pasted on the case of the GAT10-DN with the following codes.

Example of model code: 

GAT10-DN-90-0

Confirmation of Specification Codes

① ②

Ambient conditions
for operation

-20

65

5VA

100

240V AC

4VA

24V AC

3W 

24V DC

Between input/output terminals and power terminal 2300V AC 1
minute (induction current: 3mA)
Between power terminal and protective conductor terminal
1500V AC 1 minute (induction current: 3mA)

Between input/output terminals and power terminal 500V DC
20M

Ω

 min.

Between input/output terminals and protective conductor
terminal 500V DC 20M

Ω

 min.

Material of case
Color of case

External dimensions

PPO resin molding

H80xW50xD120 mm

Including base, but excluding front

connector

Black

Altitude

2000 m from the sea level or lower

Caution

Caution

Warning

Warning

Code and Description

Item

Power supply

Special note

90: 100-240V AC

0: Without

08: 24V AC/DC

9: With

100

120

50

80

8-M3.5

×

7

20

(2

)

7.8

±

0.2

51 min.

(4

)

35.

4

81 min.

2-

φ

4.5

(Unit 

mm

)

40

±

0.2

Отзывы: