CapStar Feeder Installation/Maintenance Manual
22
Electrical Wiring
The CapStar Cap Feeder is powered by AC current. The two DC
motors are controlled individually by dedicated KBIC motor
controller cards. An external speed control dial is provided for
each motor. The M1 and M2 motor speeds are independent (non-
synchronized).
➤
The Main Power Switch provides power to the electrical box.
➤
The EMERGENCY STOP cuts power to the controllers and the
motors.
➤
The Main Power Switch
must be turned off before opening the
electrical box.
Until the Main Power Switch is turned off, the
breaker(s) and the terminal strips are still powered up.
➤
The Motor 1 (M1) drives the vertical elevating belt.
➤
The Motor 2 (M2) drives the horizontal conveyor belt.
Refer to
Figures 3-8
and
3-9
for wiring schematics.