SECTION 4 – SPECIFICATIONS
4-2
Model ST460 SSS
(Synchro Shuttle Shift)
Model ST460 EHSS
(Electro Hydro Shuttle Shift)
COOLING SYSTEM
Type
Pressurized Liquid with
Recirculating Bypass
Pressurized Liquid with
Recirculating Bypass
Water Pump:
Type Centrifugal
Centrifugal
Drive
V – Belt
V – Belt
Belt Deflection
10 – 15 mm when 9 – 11 kg
thumb pressure is applied
midway between pulleys
10 – 15 mm when 9 – 11 kg
thumb pressure is applied
midway between pulleys
Fan Diameter
410 mm
410 mm
Number of Fan Blades
8
8
Thermostat:
Start to Open
71ºC
71ºC
Fully Open
82ºC
82ºC
Radiator Cap
110 kPa
110 kPa
Antifreeze
Ethylene glycol
Ethylene glycol
ELECTRICAL SYSTEM
Main system Protection
40A Slow – Blow fuse
40A Slow – Blow fuse
Number of fuses for Circuit
Protection
5
5
Alternator
12V / Heavy Duty / 55A
12V / Heavy Duty / 55A
Battery Type
12V, 64 amp. 105D31R
12V, 64 amp. 105D31R
Start HP (kw) Rating
2.7 (2.0)
2.7 (2.0)
Starting Motor
Pre-Engaged Reduction
Pre-Engaged Reduction
FUEL SYSTEM
Fuel Type
Type of Fuel to Use if
Above 4.5ºC
No.2-Diesel, Cetane Rating:
Minimum 40
No.2-Diesel, Cetane Rating:
Minimum 40
Type of Fuel to Use if
Below 4.5ºC
No.1-Diesel, Cetane Rating:
Minimum 40
No.1-Diesel, Cetane Rating:
Minimum 40
Injection Pump
Type In-Line
In-Line
Timing
18º – 20º BTDC
18º – 20º BTDC
Содержание ST460
Страница 1: ...ST460 OPERATOR S MANUAL MODEL...
Страница 67: ...SECTION 2 OPERATION 2 42...
Страница 103: ...SECTION 3 LUBRICATION AND MAINTENANCE 3 36...
Страница 104: ...SECTION 3 LUBRICATION AND MAINTENANCE 3 37...
Страница 112: ...SECTION 4 SPECIFICATIONS 4 7...
Страница 114: ...SECTION 4 SPECIFICATIONS 4 9 3 5 4 4 7 1 2 6...
Страница 119: ...SECTION 4 SPECIFICATIONS 4 14...
Страница 121: ...SECTION 4 SPECIFICATIONS 4 16...
Страница 123: ...SECTION 4 SPECIFICATIONS 4 18...
Страница 124: ...SECTION 4 SPECIFICATIONS 4 19 NOTES...
Страница 125: ...SECTION 4 SPECIFICATIONS 4 20...