8
Maintenance and Service
Annually check to ensure that your Venting system is clear. Periodically check the pilot and burner. Check
to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure
the pilot flame is blue with no or very small yellow tips.
O
PENING
T
HE
D
OOR
:
Turn unit off and wait until the appliance has cooled down.
1. Open the right hand hinged side flap, which will expose a door
fastener. Using a 1⁄2” wrench, loosen the fastener.
2. Due to the shape of the bay window door. You must also open
the left-hand side flap before attempting to open the door.
3. If the door must be removed open the door and lift the door
pins out of the hinges (see Figure 6).
4. Ensure the door is properly fastened after cleaning before
attempting to re-light the appliance.
C
LEANING
T
HE
G
LASS
:
Allow the glass to cool before cleaning.
It will be necessary to clean the ceramic glass periodically.
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with
all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass
surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary
problem. Depending upon the amount of use, cleaning should be required no more than two or three
times per season.
To clean the door, use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro
dealer. Abrasive cleaners will damage the glass.
Important note:
When the unit is turned on for the first time, It should be turned onto high without
the fan on for the first 4 hours. This will cure the paint, logs, gasket material and the other products used
in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke
and can irritate some people. After the unit has gone through the first burn turn the unit off including
the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass
cleaner.
T
O
R
EPLACE
D
OOR
:
The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a
replacement inner door with glass assembly must be purchased.
The glass in this appliance is ceramic. Remove the door with glass, a new door assembly must be
purchased from an ENVIRO dealer (part # EC-063).
Do not use a substitute materials; it will void
the warranty.
C
LEANING
T
HE
F
IREBOX
:
1. Turn off the unit and allow it to cool down completely.
2. Remove the logs carefully from the firebox. Gently remove the embers and place on a piece of paper
towel, until ready to replace.
���� ��
��� ������ �����
Figure 6: Removing the Door.