15
ignition of the arc. In the case of small parts welding it is recommended to disable this function, because it can cause burning of the work piece.
To adjust the value of the function HOT START control knob can be pressed (F) until the ignition of the respective LED. On the left is displayed on the
right and the hot current value of the function. Rotating the knob (F) may change the value. Range: 0 - 10 Value 10 corresponds to 50A.
7.2 Method of TIG LIFT
When selecting the method of TIG LIFT it is possible to adjust the welding current. Welding current adjustment knob can be adjusted. Parameters and
welding conditions can be loaded into 10 of independent memory cells (0-9) intended for TIG LIFT section 6 by B and E.
7.3 MIG
During MIG welding device can operate in synergy mode and manual. Synergic mode allows you to select the welding parameters for less experienced
users. In this mode, the device automatically selects the welding parameters depending on the type of material being welded. Manual mode allows the
user to select the welding voltage, wire feed speed and inductance as required.
DIGIMIG 225GDS welder is an automatic function 3 second delay after the end of the gas discharge welding process allowing to solidify the weld pool
crater under cover gas. In order to avoid crater porowania recommended after completion of the welding process to wait for 2-3 seconds and move the
gas nozzle from the area of the crater.
7.3.1 Mode synergistic Fe, SS, Al alloys
Welder DIGIMIG 225GDS after switching operation MIG operates as a synergistic effect, which enables the automatic selection of a set of standard
welding parameters, ie. The welding voltage and wire feed speed for selected weldable material.
Welding machine has a built-in synergic programs for selected materials, wire diameters and shielding gases in accordance with the following table:
Type of
material
Type
Mark
wire
diameter
Shielding gas -
recommended
Stal (Steel)
carbon steel
fe
0.6 / 0.8 / 1.0
WHAT
2
or Ar + CO
2
WHAT
2
or Ar + CO
2
WHAT
2
or Ar + CO
2
WHAT
2
or Ar + CO
2
(82/18)
stainless steel
SS
0.8 / 1.0
Ar + CO
2 (
82/18)
Ar + CO
2 (
82/18)
Ar + CO
2 (
82/18)
Aluminum
(ALU)
AlMg5
ER 5356
0.8 / 1.0
Argon
AlSi5
ER 4043
0.8 / 1.0
Argon
•
Argon should be used with high-class quality: 4.8 and above recommended