6
from the device it is normal and indicates proper operation of the drain valve.
Filter-dryer does not require additional user support, you only
from the device it is normal and indicates proper operation of the drain valve.
Filter-dryer does not require additional user support, you only
need to periodically its control.
Compressed air is connected to the inlet (12) at the rear of the device. It is recommended to use additional external air dryer.
Figure 2. View of the bottom wall of the device
8. FUNCTIONAL DESCRIPTION switches and DIAL
Fig. 3. View and posterior wall thinning
1. Display
2. Switch 2T / 4T / TEST
3. The current regulator cut
4. The LED air pressure
5. LED thermal protection or malfunction
6. LED improper power supply
7. Fuse
8. Air pressure gauge
9. The air pressure control knob
10. Power Cord Mass
11. The socket holder of the plasma
12. Connection Air
13. Main switch
Ready for operation, the device attached to the connector (13) located on the rear wall. Setting the cutting current is made knob (3). Value indicates the
current setting display (1), the knob (9) controlled by air pressure. Manometer indicates the pressure value (8). Switch (2) is used to control the cutter
mode (two-stroke engine / czterotakt). TEST Position is used to check the correctness of the installation of the air and its cleaning. Starting operation
after