Poisoning prevention fumes and gases evolved at the time of cutting: 

Keep your head outside the smoke, 

Use ventilation and exhaust installed in limited air exchange. 

Blow fresh air when working in a confined space (tanks) 

Use masks and respirators. 

Preventing burns: 

Wear suitable protective clothing and footwear to protect from burns from arc radiation and spatter, 

Avoid contamination of clothing lubricants and oils that may lead to its inflammation 

Explosion prevention and fire: 

Do not operate the machine and cutting in areas at risk of explosion or fire, 

The position of the cut should be equipped with fire-fighting equipment, 

The position of the cut should be at a safe distance from flammable materials. 

Preventing negative effects of noise: 

Wear earplugs or other protection against noise, 

Warn people about the danger nearby. 

WARNING!

Do not use the power source for thawing frozen pipes.

Before starting the unit: 

Check the condition of electrical and mechanical connections. It is forbidden to use handles and load wires with damaged insulation. 
Inadequate insulation handles and cables current danger of electric shock,

Ensure proper operating conditions, ie. To ensure proper temperature, moisture and ventilation in the workplace. Outdoors closed to protect from 
rain,

Place the cutter in place enabling its easy handling. Persons operating cutter should:

know and comply with health and safety regulations in force in the performance of plasma cutting, 

use proper, specialized protective equipment: gloves, apron, rubber boots, shield or welding helmet with a suitably selected filter 

know the contents of this manual cutter and operated in accordance with its intended purpose. Repair work may only be carried out 

after removing the plug from the wall socket.

When the device is connected to a network is not allowed to touch the bare hand or by wet boat depends also any elements constituting the electric 
circuit section. 
It is forbidden to remove the outer casing when the device is turned on to the network. All processing of cutting their own are prohibited and may 
constitute a deterioration in security conditions.

All maintenance and repair may only be performed by authorized persons with the conditions applicable to the safety of electrical equipment. Do not 
operate the cutter in explosive or fire! The position of the cut should be equipped with fire-fighting equipment. After working the machine power cord 
must be disconnected from the network.

The above risks and the general safety rules is not exhaustive safety while driving cuts because it does not take into account the specifics of the 
workplace. They are an important complement to bench safety instructions and training and briefings given by supervisory staff.

3. GENERAL DESCRIPTION 

Cutter CUTTER 90 CUTTER 110 serve to air plasma sheets of steel and aluminum and copper. These devices are inverters produced the most 
technologically advanced components made in IGBT technology.  

Application of inverter resulted in a significant reduction in the dimensions and weight of the equipment, which enables them to operate in particularly 
difficult to access.  
The construction and front panels for CUTTER CUTTER 90 and 110 are identical devices differ only in the parameters and brackets to be cut. 

Содержание Cutter 110

Страница 1: ...V3 1 18 03 28 USER MANUAL Inverter PLASMA CUTTING CUTTER 90 CUTTER 110...

Страница 2: ...the workplace During plasma cutting there are the following risks ELECTRIC SHOCK MAY BE FATAL ARC NEGATIVE IMPACT ON HUMAN EYES AND SKIN POISONING AND GAS fumes BURNS EXPLOSION AND FIRE HAZARDS NOISE...

Страница 3: ...ld or welding helmet with a suitably selected filter know the contents of this manual cutter and operated in accordance with its intended purpose Repair work may only be carried out after removing the...

Страница 4: ...inute break Duty cycle of 100 means that the machine can operate continuously without interruption Warning Heating test was carried out in the ambient air temperature Duty cycle at 40 C was determined...

Страница 5: ...es not affect the operation 7 CONNECTION TO THE INSTALLATION OF AIR Inside the machine is a service unit with filter dryer Filter dryer equipped with an automatic drain valve whose outlet is located i...

Страница 6: ...r wall thinning 1 Display 2 Switch 2T 4T TEST 3 The current regulator cut 4 The LED air pressure 5 LED thermal protection or malfunction 6 LED improper power supply 7 Fuse 8 Air pressure gauge 9 The a...

Страница 7: ...until the release button on the handle In this mode czterotaktu arc initiation takes place in the same way as dwutaktu mode but the arc is struck you can release the button on the handle and cut the l...

Страница 8: ...voltage Turn off the unit for 2 3 minutes and reconnect Not to bow strikes None of the competent contact wire clamp mass Correct ll of mass contact terminal Faulty switch in the handle Plasma white re...

Страница 9: ...UTS CV0011 For a full list of consumables and spare parts is available on the website and in the company www tecweld pl TECWELD There is a possibility of direct purchase of these parts 13 MAINTENANCE...

Страница 10: ...D G N D SZ2 1 2 3 4 5 6 X 3 VH 06 X 1 VH 05 1 2 3 4 5 X 2 VH 05 FAN 220VAC 0 0 220 380VAC 0 27 36VAC 15VAC 0 15VAC 2 2 0 V 0 V 3 8 0 V PHB 24 L 1 1 3mH AB 29 1 2 3 4 5 6 7 X 1 VH 07 1 2 3 4 5 6 CON11...

Страница 11: ...ust be used methods of utilization In Poland in accordance with the provisions of the Act of July 1 2005 Waste electrical and electronic equipment is prohibited to place together with other wastes of...

Страница 12: ...rective 2011 65 EU and shall comply with the following standards BS EN 60974 1 2013 04 Arc welding equipment Part 1 Welding power sources BS EN 60974 1 2013 04 Arc welding equipment Part 1 Welding pow...

Отзывы: