Temperature calibration function:
When there is deviation between the measuring temperature and standard
temperature, use the temperature calibration function, make the machine
measurements value consistent with the standard temperature, the after
calibration temperature= the before calibration tempe calibration value
(calibration value can be positive number, negative number, and 0) .
◆
Temperature calibration settings:
Press "SET" key and hold more than 3 seconds to enter the menu display,
with "▲" or "▼" key adjusted to the screen, appearing "CA" code, press the
"SET" key to display the temperature calibration settings, press "▲ "Or"▼"key to
adjust the parameters.
For example: When we measure the probe temperature was 25 degrees, it
displays 25 degrees as the CA is 0, it displays 26 degrees as the CA is 1, it
displays 24 degrees as the CA is -1. This function is generally applied when
the probe can not measure directly the measured object. For example, we
place the probe at the outside of a cup to measure its water temperature, we
need to adjust the CA parameters because of the heat loss of the cup, so that
the display temperature can be in accordance with the one of the cup.
◆ Delay Protection Function:
In the cooling mode, the first power on, when the measured value above the
OFF temperature + Difference value, the machine will not immediately start
cooling, it needs to set the delay time, then the machine can run to start
cooling; once the interval between two cooling is larger than the delay time, the
machine immediately starts cooling, once the interval between two cooling is
less than the delay time, the machine must run the remaining delay time to
start cooling. The delay time is started to calculate from stopping the machine.
The delay time of heating mode is as same as the cooling mode.
Note: It is recommended that only the device that use compressor cooling can
use the delay start function, the user who don't need delay start function
please set this parameter to 0.
◆
Delay Protection Setting:
Press "SET" key and hold more than 3 seconds to enter the menu display,
with "▲" or "▼" key adjusted to the screen, appearing "PT" code, press the
"SET" key to display the delay setting value, then press the "▲ "or "▼"key to
adjust the parameters.