3 Function parameter schedule graph
19
F9.04
Motor overload
protection coefficient
20.0-120.0
(
%
)
0.1(%) 100.0(%)
×
F9.05
Overload warning
alarm checkout level
20
-
200
(
%
)
1(%) 130(%)
○
F9.06
Overload warning
Alarm Delay time
0.0
-
20.0s
0.1s 5.0s
○
F9.07
Overvoltage stall selection
0: ban
1: allow
1 1
×
F9.08
Overvoltage stall point
120-150(%)
1(%) 140(%)
○
F9.09
Reversed
F9.10
Reversed
F9.11
Reversed
Fd –failure record function parameter group
Function
code
name
Set range
unit
Factory
default
modifi
cation
Fd.00
Previous one time failure record
Previous one time failure record
1 0 *
Fd.01
Previous two time failure record
Previous two time failure record
1 0 *
Fd.02
Previous three time failure record
Previous three time failure record
1 0 *
Fd.03
Previous four time failure record
Previous four time failure record
1 0 *
Fd.04
Previous five time failure record
Previous five time failure record
1 0 *
Fd.05
Previous six time failure record
Previous six time failure record
1 0 *
Fd.06
Set freq. of previous failure
Set freq. of previous failure
0.01Hz 0 *
Fd.07
output freq. of previous failure
output freq. of previous failure
0.01Hz 0 *
Fd.08
output current of previous failure
output current of previous failure
0.1A 0 *
Fd.09
output voltage of previous failure
output voltage of previous failure
1V 0 *
Fd.10
DC bus-bar voltage of previous failure
DC bus-bar voltage of previous
failure
1V 0 *
Fd.11
Load motor speed of previous failure
Load motor speed of previous
failure
1(r/m) 0 *
Fd.12
Module temperature of previous failure
Module temperature of previous
failure
1
℃
0 *
Fd.13
Input terminal status of previous failure
Input terminal status of previous
failure
0 *
Fd.14
Accumulative run time of previous failure Accumulative run time of previous
failure
0 *