Operation method:
Channel:
select the channel to record when camera mask occurred.
Enable:
function enable switch
Sensitivity:
there are six levels. The six-level has the highest sensitivity.
Period:
Click set button, you can see an interface is shown as below. Here you can set for
business day and non-business day. You can set up six time period, but they can’t be repeated. The
linear graphics show the period, you can copy the setting to other days
Alarm output:
when camera masking occurred, system enables peripheral alarm devices
Latch:
when camera masking, system auto delays detecting for a specified time. The value
ranges from 10-300 (Unit: second)
On-screen:
reverse display means allowing on-screen. There is connection motion on the
screen when alarm signal happens.
Send email:
System can send out email to alert you when alarm occurs.
Channel:
select the channel to activate recording function once alarm occurred. Please make
sure you have set MD record in encode interface (Main Menu->Setting->Schedule) and schedule
record in manual record interface (Main Menu->Advanced->Manual Record)
PTZ activation:
Here you can set PTZ movement when alarm occurs. Such as go to preset, tour
&pattern when there is an alarm. Click “select” button,
Tour:
Here you can enable tour function when alarm occurs. It is a one-window tour.
Recording Latch:
when motion detection complete, system auto delays recording for a
specified time. The value ranges from 10-300 (Unit: second)
Buzzer:
Default is “Off”