SWIMMING POOL HEAT PUMP

4. Maintenance

Flow switch failure

Check the water flow volume,
water pump is failure or not.

No water/little water in water
 system.

5. Malfunction and solution

Check or change the sensor

Check or change the sensor

Check or change the sensor

Check or change the sensor

Check or change the sensor

Coil1 sensor failure

Coil2 sensor failure

(proprietary for A type)

Temp is too much different 
between water-in and water-out

Water in temp
Sensor failure

Water out temp
Sensor failure

ambient sensor failure

Anti freezing
under cooling mode

The first time freezing
protection in winter

The second time freezing
protection in winter

Check the water flow volume,
or water system is jammed or not 

Check the water flow volume,
or water system is jammed or not 

The sensor is open or short circuit

The sensor is open or short circuit

The sensor is open or short circuit

The sensor is open or short circuit

The sensor is open or short circuit

Water flow volume not enough,
water pressure difference is too low 

Water flow volume is not enough

Too low 

Too low

Malfunction                                                                              Reason                                                       Solution

Wire

Controller display

PP 01

PP 02

PP 03

PP 04

PP 05

PP 06

PP 07

PP 08

PP 09

EE 03

Compressor air exhaust protection

Compressor air exhaust 
temperature too high

Power supply connections wrong
(for 3phase unit). 

3 times water-in and water-out temp
difference protection in 30minutes

Check connections of power cable.

Check the water flow volume,
or water system is jammed or not.

Check  water flow and gas pressure

Wrong connections or lack of 
connection

Water flow volume not enough, 

water pressure difference is 

too low 

EE 04

EE 05

EE06

EE 08

Defrost code
display

Wire controller and The
PCB connection failure.

Check the wire connection

defrosting

Communication failure

Check each protection point of system1
remove the malfunction according to 
System Protection Board malfunction table
(See protect 300  page 10)

Malfunction of system1 
  (for 3 phase model)

High/Low pressure protection
     (for single phase model)

The system1 protection was failure

EE 01

Malfunction of system2 

EE 02

The system2 protection was failure

Check each protection point of system2
remove the malfunction according to 
System Protection Board malfunction table
(See protect 300  page 10)

Check refrigerant pressure 

System gas pressure too high or 
too low

To check the water supply device  often. You should avoid the condition of no water or air entering 
into system, or that will influence unit’s performance and reliability. You should clear the water 
filter regularly to avoid unit’s damage by filter’ jam.

There should be dry, sanitary and ventilation around the unit. To clean the side condenser
 regularly for good heating exchanging and saving energy.

To check the power supply and cable connection often, to see if there is abnormal action or bad 
smell about the electrical component. If yes, Contact Installer immediately.

Please discharge all water in the water pump and water system lest freeze the water pump or water 
system.You should discharge the water at the bottom of water pump if the units will stop for long 
time. And you should check the units thoroughly and fill the system with water fully before power
 on the units again.

Содержание SBR-26.0H-B-S

Страница 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual English Version...

Страница 2: ...controller operation guide 3 4 Maintenance 7 5 Malfunction and solution 7 6 Wiring diagram 9 Service 1 How to Obtain Service 11 Attachment 1 The charts displayed for outdoor pool indoor pool 11 2 The...

Страница 3: ...e way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 2 Children should be supervised to...

Страница 4: ...ht Gross Weight Unit Dimension L W H Weight kg 15 40 8 30 380 3 50 Scroll Kpa RPM dB A inch 3 m h mm mm W V PH Hz W W W W A A W W BTU h W BTU h W 1 Performance data of Swimming Pool for A type Measure...

Страница 5: ...2 SWIMMING POOLHEAT PUMP 2 The dimension for Swimming Pool Heat Pump 710 686 750 1450 1060 SBR 26 0H B S SBR 50 0H A S 760 440 425 470 1115 1250 80 370...

Страница 6: ...ler 0 with cooling mode only water heater 3 with heating mode only water cooler and heater 1 and electric heater 2 with auto cooling heating 3 modes button and button Up and down button Integrating wi...

Страница 7: ...n Actual tested value Parameter checking and Setting You may enter parameter checking state from any other states by pressing once In the state of Parameter Checking each press on can check the next d...

Страница 8: ...n temp for defrosting Temperature of exit defrost under heating model Time of exit defrost under heating model System quantity Automatic restarting Model cooling only heating or cooling auxiliary elec...

Страница 9: ...the ON OFF state Keyboard Lock Unlock In default state long press and for 3 seconds AT THE SAME TIME vibrator bee once the keyboard will be locked In the state of Locked long press and for 3seconds v...

Страница 10: ...pressure Wrong connections or lack of connection Water flow volume not enough water pressure difference is too low EE 04 EE 05 EE06 EE 08 Defrost code display Wire controller and The PCB connection f...

Страница 11: ...220VAC no use 7 COMP1 Compressor of system1 220VAC 8 AC L Live wire 9 AC N neutral wire 10 KYOUT GND On Off switch output no use 11 kDOUT GND Mode output no use 12 NET GND 12V Wire controller 13 KYIN...

Страница 12: ...25 BL 26 BL 27 BL 25 BL 26 Y G 27 BRN X9 X10 N T S R System Protection PCB COMP1 VAL1 Switch for streem N T S R S Current checking Current checking 12V GND SYS GND LOW1 LP PUMP BLU BLU t t t t TEMP SE...

Страница 13: ...tion System continuously detect 3 seconds for compressor phase 1 or 2 If phase 1 or 2 current 1 system enter to compressor over current protection error code 5 When detected compressor phase 1 or 2 cu...

Страница 14: ...nately freon leaks are very uncommon and usually are due to shipping reon If your customer is having a problem and you as the installing dealer have verified that the cause is NOT external to my compa...

Страница 15: ...at night Space temperature at night Space humidity at night Some of the charts are Pool Temperature operating period 35 30 25 20 15 10 Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Maxlmum Minlmum P...

Страница 16: ...unit Space Temperature operating period 40 35 30 25 20 15 10 Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Space Temperature Maxlmum Minlmum Maxlmum Minlmum 13 SWIMMING POOLHEAT PUMP Heat pump Outle...

Страница 17: ...t Heat Pump Chlorinator 14 SWIMMING POOLHEAT PUMP Pressure type Chlorinator or Brominator In line Chlorinator or Brominator P trap Check valve Water Pump Filter Chlorinator P trap Check valve Water Pu...

Страница 18: ...Please use outside water flow switch for backup if inside one is damaged COM GND VCC T1 T2 T3 SW1 SW2 SW3 T4 15 SWIMMING POOLHEAT PUMP...

Страница 19: ...8 bushels 2 91 hectolitres American dry 1 pint 33 60 cu in 0 550 litre 1 quart 2 pints 1 101 litres 1 peck 8 quarts 8 81 litres 1 bushel 4 pecks 35 3 litres American liquid 1 pint 16 fluid oz 28 88 cu...

Страница 20: ......

Отзывы: