Parts List

3

ITEM 

NO.

PART NO.

DESCRIPTION

DIMENSION

IMAGE

QTY.

1

S1

FRAME

2000x1035

5

2

JF1

BRACKET

220x40

3

3

CB1 

BRACKET

110x110

7

4

ST1

ROOF TIE 

1025x40x40

1

5

FT1

FOOT

109X100X40

2

6

FT3

FOOT

109X100X80

4

7

RB1

BRACKET

110x46

8

8

R1

RAFTER

1130x40x40

3

9

SS

SEALING STRIP

TRIM TO 1135

1 ROLL

10

PCE1

ROOF PANEL

1135X1050

2

11

RC1 

ROOF STRIP

1130

3

12

2MD

ROOF EDGE

TRIM TO SUIT

3

13

EC40

40x40 END CAP

40X40

8

Содержание SR1551

Страница 1: ...Assembly Instructions Product Code SR1551 Doc No SR1551 01 040116 UK Email Sales shelters4less co uk Web www shelters4less co uk Tel 0800 160 1002 ...

Страница 2: ...10 11 9 4 6 5 7 3 1 8 12 2 2 Exploded View ...

Страница 3: ...3 3 CB1 BRACKET 110x110 7 4 ST1 ROOF TIE 1025x40x40 1 5 FT1 FOOT 109X100X40 2 6 FT3 FOOT 109X100X80 4 7 RB1 BRACKET 110x46 8 8 R1 RAFTER 1130x40x40 3 9 SS SEALING STRIP TRIM TO 1135 1 ROLL 10 PCE1 ROOF PANEL 1135X1050 2 11 RC1 ROOF STRIP 1130 3 12 2MD ROOF EDGE TRIM TO SUIT 3 13 EC40 40x40 END CAP 40X40 8 ...

Страница 4: ...nd Tools NOTE THE 50mm TECH SCREWS ARE FOR FIXING ROOF STRIPS RC ONLY Fittings Bolt set M10 T25 T50 BTANCM12100 M10 x 60 mm Nut Washer Black Caps 25 mm Tech screw 50 mm Tech screw M10 12 x 100 mm Concrete Bolt Pack A 30 30 60 60 72 30 8 Required 12 12 24 56 18 6 6 Spare 18 18 36 4 54 24 2 Image ...

Страница 5: ...ligned with outside CB1 JF 1 S1 Frame Step 1 Assemble the back and side frames using the S1 frames Join the frames using the CB1 brackets in the corners and the JF1 brackets on the flat joints 5 Check the dimension of the shelter to ensure correct alignment GENERAL NOTE 50mm Tech Screws are for fixing roof strips RC only ...

Страница 6: ...1 brackets in the corners and JF1 brackets on the straight joints Once the main structure is bolted together move the shelter into its final position and install foot brackets FT1 and FT3 to secure shelter to the ground Check the dimension of the shelter to ensure correct alignment ...

Страница 7: ...RB1 R1 1035 1035 Front View RB1 R1 RAFTER Step 3 Screw RB1 brackets to beams then Bolt R1 roof rafters to through RB1 brackets 7 ...

Страница 8: ...ix the RC1 strips on the edges and over the gap between the roof panels and screw in with 50mm Tech screws With a mallet tap the 2MD edge trim on to seal the roof panels Then fit the black plasic caps on exposed nuts and bolts Fit the square plastic end caps EC40 to any open ends of box sections 8 NOTE THE 50mm TECH SCREWS ARE FOR FIXING ROOF STRIPS RC ONLY SEALING STRIPS TO BE ATTACHED TO RAFTERS...

Страница 9: ...1139 25 995 1044 50 1044 50 1044 50 2115 1035 2181 HOLE CENTERS ON FEET Plan View Suggested size for concrete base 200mm oversized on all 4 sides 9 ...

Страница 10: ...NOTES 10 ...

Страница 11: ...NOTES 11 ...

Страница 12: ...rnemouth BH1 1SA MAINTENANCE To ensure your products give you many years of use we recommend that you THANK YOU FOR PURCHASING THIS PRODUCT Clean panels regularly with soapy water Ensure all fitting are tight for example after a big storm Touch up any exposed metal should it get scratched All Parts and Fixings checked by Print Name Signature ...

Отзывы: