14
There is no warranty on electrical components damaged due to power failure.
NOTE: OVER-FIRING OR DELIBERATE ABUSE CAN EASILY BE DETERMINED UPON INSPECTION AND WILL VOID THE
WARRANTY.
Always keep your wood covered year round. Dry wood will produce a higher BTU output and a longer burn time. Refer to the nameplate
on furnace for additional information.
WARNING: RISK OF FIRE
• Do not operate with the flue draft exceeding .08 water column inches (19.9 Pa).
• Do not operate with fuel loading door or ash drawer open.
• Do not store fuel or other combustible material within marked installation clearances.
• Inspect and clean flues and chimney regularly.
THIS IS A WOOD AND COAL BURNING FURNACE ONLY AND SHOULD NOT BE
ALTERED IN ANY WAY.
Canadian Requirements for Supplemental/Add-On Furnaces
• DO NOT USE DUCT ELBOWS HAVING AN INSIDE RADIUS OF LESS THAN 6 inches (150mm) ON OIL,
ELECTRIC, OR GAS FURNACES.
• DO NOT CONNECT TO A DOWNFLOW FURNACE.
• DO NOT CONNECT DUCTWORK SO THAT A REVERSE FLOW IS POSSIBLE.
• OPERATE THE GAS/OIL/ELECTRIC/ FURNACE PERIODICALLY TO ENSURE THAT IT WILL OPERATE
SATISFACTORILY WHEN NEEDED.
• CERTIFIED FOR INSTALLATION WITH APPROPRIATE DUCTWORK CONFIGURATIONS ONLY.
• DO NOT RELOCATE OR BYPASS ANY OF THE SAFETY CONTROLS IN THE ORIGINAL GAS/OIL/ELECTRIC
FURNACE INSTALLATION.
• DO NOT CONNECT TO ANY GAS FURNACE THAT HAS NOT BEEN CERTIFIED INITIALLY AS COMPLYING
WITH CAN/CGA-2.3.
• THE OPERATION OF THE GAS FURNACE MUST BE VERIFIED FOR ACCEPTABLE OPERATION BEFORE AND
AFTER INSTALLATION OF THE ADD-ON APPLIANCE BY A GAS FITTER WHO IS RECOGNIZED BY THE
REGULATORY AUTHORITY.
• DO NOT CONNECT TO ANY GAS FURNACE THAT IS NOT EQUIPPED WITH AN AIR-CIRCULATION BLOWER,
OR TO A CHIMNEY OR VENT SERVICING A GAS FURNACE OR GAS APPLIANCE.
The add-on unit should only be installed on a furnace duct system and chimney that are in good operating condition.
On a belt-driven system, blower and motor pulleys may be changed but the electrical current flowing through the motor cannot exceed the
nameplate rating. On a direct-drive system, the motor should not be changed, however, the speed of the motor may be increased. The
blower cannot be changed. This equipment should be installed, acceptable to regulatory authority, by experienced licensed personnel.
The installation should comply with requirements of CAN/CSA-B365, and changes to the installation should comply with CSA-B139 (for
oil-fired), C22.1 (for electric), or CAN/CGA-B149.1 or CAN/CGA-B149.2 (for gas-fired).