Ground mount

Roof mount

Pole mount

P

301134 A 2080200001

Serial No.

Serien Nr.

Class II Equipment

Power Output

Rated Power Output

Schutzklasse II

Leistung

Nennleistung

Alle technischen Daten unter Standard-Testbedingungen

All technical data at standard test conditions: AM 1.5; G = 1000 W/m²; T cell = 25°C

Kurzschluss-Stro m

Nennstrom

Short Circuit Current

Open Circuit Voltage

Leerlaufspannung

Rated Current

Rated Voltage

Nennspannung

MPP

150

Solar Modul Shell SP150-L

W

V

V

715

max

P

MPP

A

I

4,8

sc

A

I

4,4

MPP

V

V

43,4

oc

V

V

34,0

MPP

+- 5%

Shell Solar B.V.

P.O. Box 38000
1030 BN Amsterdam
The Netherlands

Made in Germany

Berührung eine Gefahr dar! Berühren Sie keine Anschlußklemmen, wenn das Modul Sonnenlicht

Modulen erhöht die Spannung bzw. Stromstärke. Spannungen von dreißig Volt und darüber stellen bei

erzeugt bei Einstrahlung von Sonnenlicht elektrische Energie. Jede Reihen- oder Parallelschaltung von

anleitung aufgeführten Hinweise zu Sicherheitsvorkehrungen gelesen und befolgt werden. Dieses Modul

Vor Installation, Einsatz oder Wartung dieses Produktes müssen alle in der Montage- und Gebrauchs-

Warnung! Elektrische Gefahr!

Wenn zusammen mit den Modulen Batterien verwendet werden, ist den Sicherheitshinweisen des

ausgesetzt ist. Achten Sie darauf, dass in der Nähe von entzündbaren Gasen keine Funken entstehen.

Warning! Electrical Hazard!

des Produktes hat durch qualifiziertes Personal zu erfolgen.

Booten und Campingwagen ist der entsprechende Hersteller zu Rate zu ziehen. Installation und Wartung

Inspektion erteilen die örtlichen Behörden. Für die sachgemäße Installation auf Spezialfahrzeugen wie

elektrischen Bestimmungen installiert werden. Nähere Auskünfte über Genehmigung, Installation und

konzentrieren! Module und Traggestelle müssen gemäß den lokalen Vorschriften oder den nationalen

nicht abschatten! Sonnenstrahlen nicht mit Spiegeln, Linsen oder ähnlichen Hilfsmitteln auf das Modul

wassertauglich! Vermeiden Sie Beschädigungen des Modules durch spitze, scharfe Gegenstände. Zellen

Batterieherstellers Folge zu leisten. Module nicht in Flüssigkeiten eintauchen! Das Modul ist nicht see-

voltages/amperages are additive. Thirty volts or greater is considered a shock hazard.

electricity when exposed to sunlight. When modules are connected in series/parallel,

follow all safety precautions detailed in the instruction manual. This module produces

Before attempting to install, use and maintain this product, read, understand and

Do not contact terminals when module is exposed to sunlight. Do not produce sparks near flammable
vapors. Follow safety precautions of the battery manufacturer if batteries are used with modules. Do not
immerse in liquids. Module is not sea-water-resistant! Do not wear jewelry. Do not shadow cells. Do not
expose module to concentrated sunlight with mirrors, lenses or similar means. Install module and ground
frames in accordance with local codes or the National Electrical Code. Consult local authorities for
permit, installation and inspection requirements. Consult manufacturer for proper installation on special
vehicles such as boats and camper. Product should be installed and maintained by qualified personnel.
Keep module away from children.

Each module has a label on its rear side 

providing the following information:

The Module Type name - consisting of an 

“S“ and a second letter which determines 

the cell technology, followed by a number 

that is equivalent to the rated power of the 

module.

The Serial Number - used to identify the 

specific product. Each individual module 

has a unique serial number.

Rated Power, Rated Current and Rated 

Voltage. All are characteristic values im-

portant for the design of your PV-system.

The Open Circuit Voltage exceeds the 

rated Voltage. Take care that the Open 

Circuit Voltage multiplied by the number 

of modules in series is not higher than the 

Maximum System Voltage. 

Maximum System Voltage. This voltage is 

certified per UL1703 and/or TÜV Safety 

Class II.

Warning Notes.

Do not remove the label. If the label is 

removed the product warranty will no longer 

be honoured by Shell Solar. 

Product Identification 

Mechanical Installation

Selecting the location 

Select a suitable location for installing the 

module. It should be positioned such that it 

is not shaded by other objects between 9 am 

and 3 pm on the shortest day of the year. The 

modules must be facing south in the northern 

latitudes and north in the southern latitudes. 

For detailed information on the best tilt angle 

for your installation, please consult your local 

solar power dealer.

Caution

The module should not be 

  shaded at any time of day.

Do not use modules near equipment or 

locations where flammable gases can be 

generated or can collect. 

Selecting the proper support frame 

Always observe the instructions and

safety precautions included with the support 

frame. If necessary, you can obtain more in-

formation from your dealer or sales partner.

Caution

Do not drill holes in the frame 

 

or glass of the module. Doing

 

so will void the warranty.

Modules must be securely attached to a 

surface using support frames or installation 

kits. The entire solar system must be able to 

withstand the mechanical loads that are typi-

cal for the region where it is installed. 

Make sure the support structure is strong 

enough to withstand the anticipated wind 

and snow loads according to local standards 

and regulations.

Ensure that the modules are not subjected to 

excessive forces due to thermal expansion of 

the support structure.

The support structure should be made of 

durable, corrosion-resistant and UV-resistant 

material.

Support structures and installation kits for 

many different uses are available from Shell 

Solar and specialist companies. Ask your 

dealer or sales partner for advice. 

Содержание SP150-L

Страница 1: ...Shell Solar Installation Guide for Shell Solar Photovoltaic Modules www shell com solar First Edition 2003...

Страница 2: ...service WARNING All instructions should be read and understood before attempt ing to install wire operate and maintain the module Contact with electrically active parts of the module such as terminals...

Страница 3: ...rk only under dry conditions and use only dry tools Observe the safety regulations for all other components used in the system including wiring and cables connectors charging regulators inverters stor...

Страница 4: ...dancewithlocalcodesortheNationalElectricalCode Consultlocalauthoritiesfor permit installationandinspectionrequirements Consultmanufacturerforproperinstallationonspecial vehiclessuchasboatsandcamper Pr...

Страница 5: ...ulations when installing modules on roofs and buildings and use prescribed safety equipment safety nets lifelines etc Mounting hole locations For secure installation use only the recom mended mounting...

Страница 6: ...mounting system Provide adequate rear ventilation For proper operation and to avoid damage from condensation the module requires an adequate flow of air across the rear surface When installing the mod...

Страница 7: ...s the charging current automatically adjusts to suit the charge state of the battery and the power consumption of the connected loads When using a self regulating module make sure there is sufficient...

Страница 8: ...r system Please observe the following Keep cable length as short as possible to reduce efficiency voltage drop If you connect several modules together secure the wiring to the support frame Where poss...

Страница 9: ...can cause damage to the bypass diode in the module a risk of explosion due to excessive gas generation in the battery Grounding Ground the modules and the support frame Modules with frames have a pre...

Страница 10: ...emove the knockout plug by placing the tip of a screwdriver at the edge of the plug and striking the screwdriver with a hammer Attach the fitting to the junction box and leave it loose Pass the wire t...

Страница 11: ...ket pass a short cable tie through the slot and secure the cable tie After making the electrical connections Replace the covers on the junction boxes and carefully tighten the four retaining screws 0...

Страница 12: ...any problems arise have them be inves tigated by an authorised specialist Observe the maintenance instruc tions for all components used in the system such as support frames charging regulators invert...

Страница 13: ...acting the diode lead Note the orientations of the polarity markings on the diodes Check the conductivity of the diodes They should conduct electricity when the test leads are connected in one directi...

Страница 14: ...or for reshipment of any repaired or replaced PV modules or cost associated with installation removal or reinstallation of the PV modules D When used in non land based applications the Limited Peak Po...

Страница 15: ...DE ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TOWARRANTIESOFMERCHANTABILITYANDOFFITNESS FOR PARTICULAR PURPOSE USE OR APPLICATION AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE...

Страница 16: ...0 2211 Shell Solar Industries 4650 Adohr Lane Camarillo CA 93011 United States Fax 1 805 388 6395 Shell Solar Pte Ltd 72 Bendemeer Road Hiap Huat House 07 01 Singapore 339941 Fax 65 6842 3887 Status 0...

Отзывы: