background image

Wire Diagram 

BLK

BLK

RL1 COIL

4

2

8

6

1

0

L1

L2

H

O

T

 T

E

R

M

IN

A

L

 B

L

O

C

K

INTERNAL OUTLET MATCHES POWER

LINE CONFIGURATION

100020  ~ 115V

X1000779 ~ 230V EURO

12VDC

POWER SUPPLY

BLK

WHT

+

-

SL LOGO
1750742

T

WHT

RL2 COIL

WHT

BLU

BLU

BLK

WHT(BRN)

DEFROST TIMER

DEFROST SWITCH

RED

BLK

BLK

WHT

14

13

FAN

YEL

BLK

YEL

9

1

GRY

YEL

GRY

COMPRESSOR

CONDENSER FAN

BLK

WHT

POWER LIGHT

BLK

BRN

WHT 18G

BLK 18G

INTERIOR LIGHT

DOOR SWITCH

FAN

BLK

BLK

CONTROL AREA VENTILATION FAN

4 TUBE

ELECTRONIC BALLAST

4660565

WHT

BLK

BRN

9

5

FLUORESCENT

FLUORESCENT

FLUORESCENT

FLUORESCENT

YEL

RL1

RL1

RL2

RL3

BLK

BLK

ORN

ORN

WHT

1

2

½ SS RELAY

COMPRESSOR HIGH LIM

1750506

43° C

BLK

WHT

ORN

OTP

10000J

OTP LIGHT 200020

HEAT LIGHT

200021

DEFROST HEATER

BLK

BLK

WHT

RED

RL3 COIL

891024

WHT

14

13

RED 22G

BLK 22G

½ SS RELAY

4

3

-

+

RTD



AC

98

K2

W1

K3

99

L2

S1

R1

B5

D6

D5

L3

J3

DC

Y1

N

E

U

T

R

A

L

 T

E

R

M

IN

A

L

 B

L

O

C

K

BLU

BLU

RED

RED

YEL

POWER
SWITCH

9851057

dlr   rev  6/22/09

POWER RELAY

115V  - 7030511
230V  - 7030520

7850532

6750507

891024

210002

1750538

LOW LIMIT

200021

102162

PM6R2CJ-1AAEAAA

1750816

103070

*

*

*

*

*

*

*

THESE ITEMS ARE PART OF THE BASIC

FREEZER UNIT.

SMI P/N 0300506

4880550

4650538  x4

X1000124

EMC FILTER

(USED ON CERTAIN 230VAC

MODELS)

BLK

WHT

BLK

WHT

WHT(BRN)

BLK

CONNECTIONS TO RL1

OR

EMC FILTER

20A

CKT BKR

1100500

IEC-320 INLET

CONNECTIONS TO RL1

20A

CKT BKR

1100500

CONNECTIONS TO  RL1

OR

EMC FILTER

FROM POWER CORD

OR

INLET

230V WIRING

230V WIRING

230V WIRING

230V WIRING

FAN

4880555

CHAMBER AREA CIRCULATING FAN

115V

WIRING

115V

WIRING

STEP-DOWN

TRANSFORMER

USED IN 230V

UNITS ONLY

103372

BRN

BLK

1100500

1100500

20A

CKT BKR

20A

CKT BKR

115V

230V

CONNECTIONS TO RL1

OR

EMC FILTER

NOTE:

 LOGO AND POWER SUPPLY ARE NOT USED IN ALL MODELS.

WIRING MAY INCLUDE A SECOND

CIRCUIT BREAKER IN THE

WHITE(BROWN) LINE.

 

 

Содержание RF02033111

Страница 1: ...LOW TEMPERATURE DIURNAL ILLUMINATION INCUBATOR MODEL RF2015 Serial Number RF02033111 INSTALLATION AND OPERATION MANUAL REV 09 10 4861428...

Страница 2: ...ROUBLESHOOTING SECTION 8 0 PARTS LIST UNIT SPECIFICATIONS WIRE DIAGRAMS This unit is a general purpose Diurnal Growth Chamber for professional industrial or educational use where the preparation or te...

Страница 3: ...r will arrange for official inspection to substantiate your claim 1 3 Return Shipment Save the shipping crate until you are sure all is well If for any reason you must return the unit first contact yo...

Страница 4: ...r circulation around the unit allow a minimum of 20cm between incubator and any walls or partitions which might obstruct free air flow 2 3 Lifting Handling These units are heavy and care should be tak...

Страница 5: ...when cleaning and assure all volatile or flammable cleaners are evaporated and dry before reattaching the unit to the power supply...

Страница 6: ...tes that you should consult your manual for further description and discussion of a control or user item 2 Indicates Temperature 3 Indicates Overtemperature 4 C Indicates Degrees Centigrade 5 Indicate...

Страница 7: ...ain Controllers set point If temperature rises to the Over Temperature set point this thermostat takes control of the heating element and allows continued use of the incubator until the problem can be...

Страница 8: ...ower switch to the ON position and turn each Overtemperature Thermostat to its maximum position clockwise using a coin or flat edged tool 5 2 Place a certified reference thermometer not supplied in th...

Страница 9: ...he day cycle first To stop the program push the EZ1 Button again Note When stopping the program the control will remain in the condition that it is previously in To restart the program push the EZ1 Bu...

Страница 10: ...EXT BOTTOM DISPLAY SCREEN PUSH UP OR DOWN ARROWS TO SELECT HOUR OF DAY IN UPPER DISPLAY PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN PUSH UP OR DOWN ARROWS TO SELECT MINUTES OF HOUR IN UPPER DISPLAY PUSH...

Страница 11: ...HANGE UPPER DISPLAY TO HOUR OF DAY PUSH ONCE FOR NEXT SCREEN USE UP OR DOWN ARROWS TO CHANGE UPPER DISPLAY TO MINUTE OF HOUR HOUR OF DAY MINUTE OF HOUR PUSH ONCE FOR NEXT SCREEN USE UP OR DOWN ARROWS...

Страница 12: ...H ONCE FOR NEXT BOTTOM PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN TO SELECT S tyP IN TOP DISPLAY USE UP OR DOWN ARROWS TO SELECT 12 IN TOP DISPLAY PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN PUSH ONCE FOR...

Страница 13: ...IN TOP DISPLAY PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN USE UP OR DOWN ARROWS TO SELECT oFF IN TOP DISPLAY PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN USE UP OR DOWN ARROWS TO SELECT 4 IN TOP DISPLAY PU...

Страница 14: ...rent Set Point Temperatures This program uses one 1 file and six 6 different Steps Step 1 Is an unused Step and is reserved for starting the program at Specific Time Step 2 Parameters are for entering...

Страница 15: ...S TO SELECT DESIRED SET POINT IN TOP DISPLAY PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN TO SELECT 0 IN TOP DISPLAY USE UP OR DOWN ARROWS TO SELECT 0 IN TOP DISPL...

Страница 16: ...OTTOM DISPLAY SCREEN USE UP OR DOWN ARROWS TO SELECT on IN TOP DISPLAY USE UP OR DOWN ARROWS PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN USE UP OR DOWN ARROWS TO SELECT 0 IN TOP DISPLAY hoUr hoUr 11 Min...

Страница 17: ...PLAY SCREEN Ent 1 USE UP OR DOWN ARROWS TO SELECT oFF IN TOP DISPLAY PUSH ONCE TO RETURN PREVIOUS SCREEN S tyP USE UP OR DOWN ARROWS TO SELECT SoAh IN TOP DISPLAY S tyP SoAh PUSH ONCE FOR NEXT BOTTOM...

Страница 18: ...FOR NEXT BOTTOM DISPLAY SCREEN USE UP OR DOWN ARROWS TO SELECT 2 IN TOP DISPLAY PUSH ONCE FOR NEXT BOTTOM DISPLAY SCREEN USE UP OR DOWN ARROWS TO SELECT 0 IN TOP DISPLAY PUSH ONCE FOR NEXT BOTTOM DIS...

Страница 19: ...N TO NORMAL DISPLAY A1 oPEr OR UNTIL SCREEN APPEARS AFTER THE OFFSET HAS BEEN ENTERED ALLOW UNIT TO STABALIZE RECHECK TEMPERATURE AGAIN AND IF CALIBRATION IS WITHIN EXCEPTABLE LIMITS THE OFFSET VALUE...

Страница 20: ...OR UNTIL SCREEN APPEARS nonE Usr S Usr S SET 1 PUSH ONCE PUSH TWICE 20 0 20 0 TO RETURN TO NORMAL DISPLAY SELECTING SET 1 UNDER Usr S SAVES THE OFFSET CALIBRATION FOR THE NIGHT CYCLE BEFORE CALIBRATIO...

Страница 21: ...in the chamber will spike and the Main temperature Controller will cycle off shutting down the heating element When the compressor is activated the temperature will stabilize at set point 6 2 Cleanin...

Страница 22: ...connection check shadow box for loose connections Unit will not heat over a temperature that is below set point 1 confirm that fan is moving and that amperage and voltage match data plate check fan mo...

Страница 23: ...ometer don t match 1 calibration error see section 5 9 2 controller failure evaluate if pilot light is operating correctly 3 allow at least two hours to stabilize 4 see if reference thermometer is cer...

Страница 24: ...not miss aligned 2 Steady internal clicking may be broken spring or valve call Customer Service MECHANICAL Motor doesn t move 1 if shaft spins freely check connections to motor and check voltage to m...

Страница 25: ...ce 2 check fuse circuit breaker on unit or in wall 3 see if unit is on e g fan or heater and just controller is off 4 check all wiring connections especially around the on off switch Contamination in...

Страница 26: ...t 4660505 4660505 High Limit Control 1750862 1750862 Interior Outlet 6100525 6100526 Interior Outlet European NA 6100531 Low Limit Control 1750538 1750538 Main Temperature Control 1750855 1750855 Pilo...

Страница 27: ...ons Shipping Weight 400 lbs Net Weight 280 lbs Exterior LxDxH in 34 5 x 32 x 77 Interior LxDxH in 27 x 23 5 x 57 Capacity 20 3 Cubic Ft Capacity 257 Bottles Temperature Range 10 to 40 C Temperature Un...

Страница 28: ...RED22G BLK22G SSRELAY 4 3 RTD AC 98 K2 W1 K3 99 L2 S1 R1 B5 D6 D5 L3 J3 DC Y1 NEUTRAL TERMINAL BLOCK BLU BLU RED RED YEL POWER SWITCH 9851057 dlr rev 6 22 09 POWERRELAY 115V 7030511 230V 7030520 7850...

Отзывы: