Shearwater Petrel
Average Depth
Displays the average depth of the current dive, updated once
per second�
When not diving, shows the average depth of the last dive�
Average Depth in Atmospheres (AvgATM)
The average depth of the current dive, measured in absolute
atmospheres (i�e� a value of 1�0 at sea level)� When not
diving, shows the average depth of the last dive�
Maximum Depth
The maximum depth of the current dive�
When not diving, displays the maximum depth of the last
dive�
CNS Toxicity Percentage
Central Nervous System oxygen toxicity loading percentage�
Flashes Red
when 100 or greater�
The CNS percentage is calculated continuously, even when
on the surface and turned off� When deco tissues are reset,
the CNS will also be reset�
PPO2 (average PPO2)
Only relevant when external PPO2 monitoring is used, since
other modes already show PPO2 on the center row�
The purpose of this value is to show what PPO2 is actually
being used for decompression calculations�
When three external sensors are used, the Petrel votes on
the three measured values to decide what is the most likely
true PPO2� This value shows the result of the voting�
Also, when using external sensors and you have bailed
out to OC, the center row continues to display the external
measured PPO2� Use this info display to see the OC PPO2�
In CC mode, displays in
Flashing Red
when less than 0�40
or greater than 1�6�
In OC mode, displays in
Flashing Red
when less than 0�19
or greater than 1�65�
5O
ft
2.52
AVG
AvgATM
26O
ft
11
1OO
MAX
CNS
CNS
.98
.16
.36
PPO2
PPO2