33
VL-Z1U
[Execution of adjustment]
Adjustment of servo and system controller
1. System code setting
It is necessary to set the following data items after replacing IC705 (E
2
PROM).
<Adjusting method>
Select the VCR adjustment mode and set the data value at each address.
• Automatic adjustment
Mode
VCR adjustment mode
Adjusting
1) Using command 12, select the VCR adjustment mode.
method
2) Using command 20, enable writing to the E
2
PROM.
3) Using command 22, set the above-shown system codes according to the model.
4) Using the command, inhibit writing to the E
2
PROM.
5) Using the command, exit the VCR adjustment mode.
Examples
• Replacement of E
2
PROM (IC705)
• Manual adjustment
Mode
VCR ADJ mode
Adjusting
1) Set the CAM/OFF/VCR selector switch to VCR.
method
2) Press "CONTINUE"
→
"VCR adjustment" on the remote control to enter the VCR mode.
(At this time, "VCR ADJ" is displayed in the lower left part.)
Enter the specified value at each address.
· Shown below is the procedure for setting.
3) Select an address by increasing or decreasing the flashing numeric value with the FF or REW key
and press the PB key to confirm it.
4) Set the flashing numeric value to the specified value by increasing or decreasing it with the FF or
REW key and press the PB key to confirm it.
5) Press the STOP key to make it possible to select an address.
6) Repeat steps (3), (4) and (5) above until all the data items are set. Then press "CONTINUE" to exit
the VCR mode.
7) Set the CAM/OFF/VCR selector switch to OFF.
Examples
·Replacement of E
2
PROM (IC705)
2. Adjustment of HSWP
Mode
VCR ADJ mode
Adjusting
1) Select the video mode and play back the alignment tape.
method
2) Press "CONTINUE"
→
"HSWP ADJ" keys on the remote control.
→
HSWP adjustment execution (When the adjustment is completed, "GOOD" is displayed on the LCD and
ejecting is performed automatically.)
If adjustment cannot be made, "NG" is displayed on the LCD.
Examples
· Replacement of mechanism · Replacement of E
2
PROM
Code
Specifications Destination Specifications
Menu setting
Software switching
Calendar
Address
01
09
02
0A
03
0B
04
0C
05
0D
07
0F
A9
56
01
FE
B6
49
00
FF
00
FF
03
FC
Code
1394/exif model name
Address
1A1
1A2
1A3 1A4
1A5
1A6
1A7
1A8 1A9
1BD 1BE
1BF
56
4C
2D
5A
31
55
00
00
00
00
00
00
* After replacing IC705 (E
2
PROM), make the following settings and then make adjustments.
(E
2
PROM) data table
(1) Magnetic parametric system
Address
27
28
2B
25
26
Data
70
90
A0
70
A0
Содержание Viewcam VL-Z1U
Страница 26: ...26 VL Z1U 9 5 4 Diagram of greasing oiling locations ...
Страница 57: ...57 VL Z1U M E M O ...
Страница 58: ...59 58 VL Z1U VL Z1U 14 SCHEMATIC DIAGRAMS 14 1 OVERALL SCHEMATIC DIAGRAM ...
Страница 89: ...120 A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 VL Z1U 14 32 MECHA REVERSION DETECTION SCHEMATIC DIAGRAM ...
Страница 90: ...121 A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 VL Z1U 14 33 HOLE SENSOR UNIT SCHEMATIC DIAGRAM ...
Страница 107: ...140 VL Z1U M E M O ...