E-11
SPECIFICATIONS
How to replace the Plasmacluster Ion Generating Unit
1
2
3
Remove the claw
Insert to the claw.
Take the unit holder. (see E-9)
Remove the claw of unit holder and remove
the Plasmacluster Ion Generating Unit.
Please do not dispose of the unit holder.
1 Attach a new Plasmacluster Ion
Generating Unit to the unit holder.
2 Reattach the unit holder to the main unit.
3 Reattach the main unit cover and
fi
lter cover.
Insert the car adapter in the accessory socket and check the unit replacement
light is turned OFF.
• After replacement, you may hear the sound “Zi, Zi ...”(sound
generated by Plasmacluster Ion) become louder, however, it is simply
because the Plasmacluster Ion Generating Unit has been replaced
with a new one. It is not a failure.
Note
Model
UJ-GC20E
Power
Car Adapter
Rated input
DC12V
Rated output
DC5V(Max.2A for 2 ports)
Operation mode
LOW
MED
TURBO
Power consumption
0.5W
0.7W
1.8W
Ion density
Approx. 7,000
ions/cm
3
Approx. 25,000
ions/cm
3
Approx. 75,000
ions/cm
3
Operating noise level
19dB
23dB
36dB
Outer dimensions
Upper dimension: 74mm / Lower dimension 65mm /
Height: 162mm
(Excluding accessories)
Weight
Approx. 265g (Excluding accessories)
Capacity applicable for high-density
Plasmacluster 25000
1
Approx.3.6m
3 2
1 It is the index of capacity that approximately 25,000 ions blown out to the air can be
measured at the point near the center of the space (0.5m height from
fl
oor) when the
air volume is "MED" by placing the unit at the place supposing a cup holder beside
the driver's seat.
2 Space corresponding to a cabin measuring 1.5 (width) x 2.4 (depth) x 1.0 (height)
meters.
Some speci
fi
cations may be changed for improvement purposes.