7
1. Remove 5 screws holding the condenser ass’y.
2. Disconnect 2 terminals lead wire from thermostat.
3. Remove 2 screws holding the thermostat to the thermo fixing plate.
4. Now the thermostat is free.
REMOVE OF THERMOSTAT
1. Remove the terminal cover.
2. Remove the screw holding the power cord ass’y
3. Remove 2 closed terminal to power cord ass’y.
4. Now the power cord ass’y is free.
REMOVE OF POWER CORD ASS’Y
REMOVE OF FUSE ASS’Y
1. Remove the thermostat in accordance with “REMOVE OF THERMOSTAT”.
2. Disconnect the lead wire fuse.
3. Now the fuse is free.
Thermostat
Terminal
Condenser ass’y
Screw
Screw
Screw
Thermo fixing plate
Fig. 4
Cover strap
Terminal cover
Thermo motor
Closed terminal
Power cord ass’y
Screw
Compressor
Stand
Fig. 3
PTC relay
Содержание SB-29
Страница 4: ...4 WIRING DIAGRAM CIRCUIT DIAGRAM ...