R939(W)
11 – 7
5. Hold the door panel to the door frame with eight (8) screws.
6. Re-install choke cover to door panel by clipping into position.
7. Locate door panel hinge pins into cavity hinge location holes.
8. Re-install the door stopper to the chock cover.
NOTE:
After any service to the door;
1)
Make sure that the monitor switch, monitored latch
switch and stop switch are operating properly. (Refer
to chapter “Test Procedures”.).
2)
An approved microwave survey meter should be used
to assure compliance with proper microwave radiation
emission limitation standards. (Refer to Microwave
Measurement Procedure.)
3. After any service, make sure of the following:
1. Door latch heads smoothly catch latch hook through latch holes
and that latch head goes through centre of latch hole.
2. Deviation of door alignment from horizontal line of cavity face plate
is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity face plate.
4. Check for microwave leakage around door with an approved micro-
wave survey meter. (Refer to Microwave Measurement Procedure.)
NOTE: The door on a microwave oven is designed to act as an elec-
tronic seal preventing the leakage of microwave energy from
oven cavity during cook cycle. This function does not require
that door be air-tight, moisture (condensation)-tight or light-
tight. Therefore, occasional appearance of moisture, light or
sensing of gentle warm air movement around oven door is not
abnormal and do not of themselves, indicate a leakage of
microwave energy from oven cavity.
Figure C-8. Door Replacement
Upper oven hinge
Lower oven
hinge
Lower
oven
hinge
Pin
Door
assembly
Pin