36
R-820BK
R-820BW
7. Release two (2) pins of door panel from two (2) holes of
upper and lower oven hinges by lifting up.
8. Now, door sub assembly is free from oven cavity.
9. Remove the four (4) screws holding the door panel to the
door frame.
10.Release door panel from seven (7) tabs of door frame by
sliding door panel downward.
11.Now, door panel is free.
12.Slide latch head upward and remove it from door frame
with releasing latch spring from door frame and latch
head.
13.Now, latch head and latch spring are free.
14.Remove the two (2) screws holding the glass stopper to
the door frame.
15.Remove the glass stopper from the door frame.
16.Slide the front door glass left and then slide upwards to
release the tabs holding it.
17.Now, the front door glass is free
RE-INSTALL
1. Re-install the front door glass to the door frame as
follows.
1-1. Insert the lower edge of the front door glass into the six
(6) tabs of the door frame.
1-2. Slide the front door glass upwards and insert the upper
edge of the front door glass into the five (5) tabs of the
door frame.
1-3. Slide the front door glass right and insert the right edge
of the front door glass into the two (2) tabs of the door
frame.
2. Re-install the glass stopper to the door frame as follows.
2-1. Re-install the glass stopper to the door frame so that the
two (2) holes of the glass stopper meet the two (2) pins
of the door frame.
2-2. Hold the glass stopper to the door frame with the two (2)
screws.
3. Re-install the latch spring to the latch head. Re-install the
latch spring to the door frame. Re-install latch head to
door frame.
4. Re-install door panel to door frame by fitting seven (7)
tabs of door frame to seven (7) holes of door panel.
5. Hold the door panel to the door frame with four (4)
screws.
6. Catch two (2) pins of door panel on two (2) hole of upper
and lower oven hinges.
7. Re-install choke cover to door panel by pushing.
Note: After any service to the door;
(A) Make sure that door sensing switch and secondary
interlock switch are operating properly. (Refer to
chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards. (Refer to
Microwave Measurement Procedure.)
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of cavity
Upper Oven
Hinge
Upper
Oven
Hinge
Lower
Oven
Hinge
Lower
Oven
Hinge
Pin
Pin
Choke Cover
Door
Panel
face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter. (Refer to Microwave
Measurement Procedure.)
Note: The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of microwave
energy from oven cavity during cook cycle. This
function does not require that door be air-tight,
moisture (condensation)-tight or light-tight. Therefore,
occasional appearance of moisture, light or sensing
of gentle warm air movement around oven door is not
abnormal and do not in themselves indicate a leakage
of microwave energy from oven cavity.
Figure C-7. Door Replacement