25
R -610DK
R-610DW
R -610 DS
12.Remove the fan motor with the fan motor mounting angle
from the fan case assembly and the cross flow fan.
13.Remove the two (2) screws holding the fan motor
mounting angle to the fan motor.
14.Now, the fan motor is free.
1. Disconnect the power supply cord.
2. Remove turntable and turntable support from oven cavity.
3. Lay the oven on it's backside. Remove the turntable
motor cover by snipping off the material in four corners.
4. Where the corners have been snipped off bend corner
areas flat.
5. Disconnect wire leads from turntable motor.
(See "Positive lock connector removal")
6. Remove two (2) screws holding turntable motor to oven
TURNTABLE MOTOR REMOVAL
cavity.
7. Remove the TTM packing from the turntable motor
shaft.
8. Now the turntable motor is free.
9. After replacement use the one (1) screw to fit the
turntable motor cover.
CAUTION: NO SHARP EDGES MUST BE EVIDENT AF-
TER REMOVAL OF THE TURNTABLE MO-
TOR COVER.
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
Figure C-3. Positive lock
®
connector
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Open covers of the terminal insulator by using small flat
type screw driver.
5. Remove the receptacle from the terminal insulator.
6. Now, the terminal insulator is free.
Installation
TERMINAL INSULATOR REPLACEMENT
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
1. Insert the receptacle into terminal insulator.
2. Close covers of the terminal insulator, as shown below.
3. Reconnect all leads removed from components during
testing.
4. Reinstall the outer case (cabinet).
5. Reconnect the power supply cord after the outer case is
installed.
6. Run the oven and check all functions.
Terminal
insulator
Flat type
screw driver
Receptacle
Covers
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Disconnect the wire leads from the switches.
5. Push outward on the one (1) retaining tabs holding
switch in place.
6. The switch is now free.
DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH REMOVAL
Reinstallation
1. Re-install each switch in its place. The secondary
interlock/monitor switches are in the lower position and
the door sensing switch is in the upper position.
2. Re-connect wire leads to each switch.
Refer to pictorial diagram.
3. Make sure that the monitor switch is operating properly
and check continuity of the monitor circuit. Refer to
chapter "Test Procedure" and Adjustment procedure.
Figure C-4(a). Terminal insulator
Figure C-4(b). Terminal insulator