16
R- 610DK
R-610DW
R -6 10 DS
WARNING : The oven should be fully assembled before following procedure.
(1) Place one cup of water in the center of the turntable tray in the oven cavity.
(2) Close the door, touch the " COMPU DEFROST " pad twice.
(3) Touch the Number pad " 5 " and then touch the " START " pad.
(4) The oven is in Compu Defrost cooking condition.
(5) The oven will operate as follows. (in case of Steak/Chops 0.5lb)
WEIGHT
1ST STAGE
2ND STAGE
LEVEL
TIME
LEVEL
TIME
0.5lb
60%
30sec.
40%
30sec.
(6) If improper operation is indicated, the control unit is probably defective and should be checked.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60 seconds.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin No. 1 of the 2 pin connector (A) and the normal
open terminal of the relay RY1 on the control unit with an A.C. voltmeter.
The meter should indicate 120 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated .......................... Defective relay.
DC. voltage not indicated .................... Check diode which is connected to the relay coil. If diode
is good, control unit is defective.
RELAY SYMBOL
OPERATIONAL VOLTAGE
CONNECTED COMPONENTS
RY1
Approx. -13.4V D.C.
Oven lamp / Turntable motor / Cooling fan motor
RY2
Approx. -12.6V D.C.
Power transformer
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
10. To discharge the high voltage capacitor. wait for 60 seconds.
11. Reconnect all leads removed from components during testing.
12. Re-install the outer case (cabinet).
13. Reconnect the power supply cord after the outer case is installed.
14. Run the oven and check all function.
K
RELAY TEST
L
COMPU DEFROST TEST
M
FOIL PATTERN ON THE PRINTED WIRING BOARD TEST
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on
the PWB, this foil pattern acts as a fuse.
1. Foil pattern check and repairs.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) To discharge the high voltage capacitor, wait for 60 seconds.
4) Follow the troubleshooting guide given below for repair.