11
R-430CS
A
MAGNETRON ASSEMBLY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
Home fuse or circuit breaker blows
when power cord is plugged into
wall receptacle
Monitor fuse blows when power
cord is plugged into wall receptacle.
All letters and indicators do not
appear in display when power cord
is first plugged into wall outlet.
Display does not operate properly
when STOP/CLEAR key is
touched. (Buzzer should sound and
":" or time of day should appear in
display.)
Oven lamp does not light when door
is opened.
Oven lamp does not go out when
door is closed.
Oven lamp lights but fan motor
and turntable motor do not operate.
Oven does not go into cook cycle
when START pad is touched
Oven seems to be operating but
little or no heat is produced in oven
load. (Food incompletely cooked or
not cooked at all at end of cook
cycle.)
Oven goes into a cook cycle but
extremely uneven heating is
produced in oven load (food).
Oven does not cook properly when
programmed for Cooking Power 5
mode. (Operates properly on
Cooking Power 10 (HIGH) mode.)
Oven goes into COMPU DEFROST
but food is not defrosted well.
AH sensor does not end during
sensor cooking condition. (Oven
does not shut off after a cup of
water is boiling by sensor cooking)
Oven stops at 16 sec. after starting.
OFF
CONDITION
PROBLEM
CONDITION
SHORT IN POWER CORD
SHORT OR OPENED WIRING
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE CAPACITOR
CAVITY TEMPERATURE FUSE
MAGNETRON TEMPERATURE FUSE
PRIMARY INTERLOCK SYSTEM
SECONDARY INTERLOCK SWITCH
MONITOR SWITCH
MONITOR FUSE
OVEN LAMP OR SOCKET
COOLING FAN MOTOR
TURNTABLE MOTOR
TOUCH CONTROL PANEL
WRONG OPERATION
LOW VOLTAGE
DIRTY OVEN CAVITY
KEY UNIT
RELAY (RY1)
COMPU DEFROST
FOIL PATTERN ON PWB.
AH SENSOR
POSSIBLE CAUSE
AND
DEFECTIVE PARTS
TEST PROCEDURE
RE RE A B C D E E F
F G
H RE RE CK I CK CK CK J K L M N
COOKING
CONDITION
CK = Check / RE = Replace
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
SENSOR
COOKING
CONDITION