6
R - 4 0 5 H K
R-405HW
R -403HW
Key Unit
Pin
NO. G1
Pin
NO. G13
Key unit ribbon cable
Key unit (Membrane Switch) front view
G10
G11
G12
G13
G9
G8
G7
G6
G5
G4
G3
G2
G1
POPCORN
9
3
6
2
5
8
0
1
4
7
TIMER
CLOCK
COOK
START
STOP
CLEAR
POWER
LEVEL
CLEAR
DEFROST
MINUTE
PLUS
REHEAT
*
*
*
*
When door is close, key can be operated.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
J
KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Using an ohmmeter and referring to the key unit matrix indicated on the control unit circuit, check the
circuit between the pins of the key unit that correspond to the CLEAR pad. When the pad is pressed,
the ohmmeter should indicate short circuit. When the pad is released, the ohmmeter should indicate
open circuit. If incorrect readings are obtained, the key unit is faulty and must be replaced. About the
other pads, the above method may be used.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
R-405HK/HW
R-403HW
G10
G11
G12
G13
G9
G8
G7
G6
G5
G4
G3
G2
G1
POPCORN
9
3
6
2
5
8
0
1
4
7
TIMER
CLOCK
COOK
START
STOP
CLEAR
POWER
LEVEL
DEFROST
MINUTE
PLUS
REHEAT
Содержание R-403HW
Страница 17: ...15 R 405HK R 405HW R 403HW NOTES ...
Страница 18: ...16 R 405HK R 405HW R 403HW NOTES ...
Страница 19: ...17 R 405HK R 405HW R 403HW NOTES ...