27
R-360EG
R-360ES
R-360EW
R - 360EZ
NOTE: When carrying out any repair to the door, do not
bend or warp the slit choke (tabs on the door
panelassembly) to prevent microwave leakage.
11.Release two (2) pins of door panel from two (2) holes of
upper and lower oven hinges by lifting up.
12.With pulling out the 7-pin wire harness from the hole of
the oven cavity front plate and the front cover. Remove
the door from the oven cavity.
13.Now, the door is free from the oven cavity.
REINSTALLATION
1. Insert the 7-pin wire harness to the holes of the front
cover and the oven cavity front plate.
2. Catch two (2) pins of door panel on two (2) hole of upper
and lower oven hinges.
3. Re-install choke cover to door panel by pushing.
4. Connect the 7-pin wire harness to the power unit on the
base plate.
5. Re-install the front cover to the oven cavity front plate.
6. Hold the front cover to the base plate with (2) screws.
7. Now the door is installed.
Note: After any service to the door;
(A) Make sure that door sensing switch and primary
interlock switch are o/perating properly. (Refer to
chapter “Test Procedures”.).
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of cavity
face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter. (Refer to Microwave
Measurement Procedure.)
Note: The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of
microwave energy from oven cavity during cook cycle.
This function does not require that door be air-tight,
moisture (condensation)-tight or light-tight. Therefore,
occasional appearance of moisture, light or sensing
of gentle warm air movement around oven door is
not abnormal and do not of themselves indicate a
leakage of microwave energy from oven cavity.
Figure C-6. Door Replacement
Figure C-7. Routing of 7-pin wire harness
SEALER FILM
Installation
1. Put the adhesive tape on the backing film of the sealer
film as shown in Fig. C-8.
2. Tear the backing film by pulling the adhesive tape.
3. Put the pasted side of the sealer film on the door panel.
Figure C-8. Sealer film
Door frame
Front cover
Front cover
7-pin wire
harness
7-pin wire
harness
Power unit
Base plate
Hole
Hole
Door
Pin
Pin
Upper oven
hinge
Upper
oven hinge
Lower
oven hinge
Lower
oven hinge
Door frame
assembly
Choke cover
Slit choke of
door panel
Sealer film
Backing film
Adhesive tape
DOOR PANEL
1. Disconnect the power supply cord.
2. Remove the door from the oven. Refer to "DOOR
REPLACEMENT".
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. The choke cover should have been removed.
5. Remove the four (4) screws holding the door panel to
INDIVIDUAL DOOR PARTS REMOVAL
the door screen.
6. Now, door panel is free.
LATCH HEAD AND LATCH SPRING
7. Slide the latch head and remove it from the door frame
assembly with releasing the latch spring from the door
frame assembly and the latch head.