R-350D
16
23
P24
OUT
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1). The square
waveform voltage is delivered to the RY1 driving
circuit and RY2 control circuit.
24
P25
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cooking
and "H" level while not cooking. In other cooking
modes (variable cooking) the signal turns to "H"
level and "L" level in repetition according to the
power level.
(ON and OFF times for other power level.)
25-26
P26-P27
OUT
Terminal not used.
27-34
P30-P37
OUT
Terminal not used.
35
CVCC
IN
Connected to GND.
36
VSS
IN
Power source voltage: -5.0V.
The power source voltage to the LSI is input to VSS terminal. Connected to VC.
37-38
V3-V2
IN
Terminal not used.
39-40
V1-V0
IN
Power source voltage input terminal.
Standard voltage for LCD. Connected to GND.
41
VCC
IN
Power source voltage: GND (0V).
The power source voltage to drive the LSI is input to VCC terminal.
42-45
COM4-COM1
OUT
Terminal not used.
46-65
SEG1-SEG20
OUT
Terminal not used.
66-79
P74-P91
OUT
Data output terminal to LCD driver IC3.
80-85
SEG35-SEG40
OUT
Terminal not used.
86
P40
OUT
Terminal not used.
87
P41
IN
Signal similar to AN10.
When either G13 line on key matrix is touched, a corresponding signal will be input into
P41.
88
P42
IN
Signal similar to AN10.
When either G12 line on key matrix is touched, a corresponding signal will be input into
P42.
89
IRQ0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
90
AVCC
IN
A/D converter power source voltage.
The power source voltage to drive the A/D converter in the LSI. Connected to GND.
91-92
AN0-AN1
IN
Connected to GND through resistor.
93
AN2
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
94
AN3
IN
Connected to VC through resistor.
95-98
AN4-AN7
IN
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
99
AN8
IN
Input terminal to judge the model.
The signal out of P11 will be input into AN8 through G7 line on key matrix. The LSI will judge
the model by this signal.
100
AN9
IN
Signal similar to AN10.
When either G11 line on key matrix is touched, a corresponding signal will be input into
AN9.
Pin No.
Signal
I/O
Description
20.0 msec.
During cooking
H : GND
L : -5V
P-HI
H : GND
L : -5V
H : GND
L : -5V
P-70
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
20.0 msec.
H : GND
L : -5V
Содержание R-350D