4
R- 340DK
R-340DW
ITEM
DESCRIPTION
Power Requirements
120 Volts / 14 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output
1150 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions
Width 20-1/2"
Height 11-7/8"
Depth 17-1/8"
Cooking Cavity Dimensions
Width 14-3/4"
Height 8-3/4"
1.2 Cubic Feet
Depth 15-3/4"
Control Complement
Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
POWER 100% ................................. Full power throughout the cooking time
POWER 90% .................................................... approx. 90% of Full Power
POWER 80% .................................................... approx. 80% of Full Power
POWER 70% .................................................... approx. 70% of Full Power
POWER 60% .................................................... approx. 60% of Full Power
POWER 50% .................................................... approx. 50% of Full Power
POWER 40% .................................................... approx. 40% of Full Power
POWER 30% .................................................... approx. 30% of Full Power
POWER 20% .................................................... approx. 20% of Full Power
POWER 10% .................................................... approx. 10% of Full Power
POWER
0% .................................. No power throughout the cooking time
TOUCH SCREEN, MINUTE PLUS pad, STOP/CLEAR pad
START pad, ONE TOUCH SENSOR pads
6 X 6 NO GUESS COOKING pads
More From Your Microwave pad
Beverage Center pad, Defrost pad, Set Up pad
Oven Cavity Light
Yes
Safety Standard
UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The electrical requirements are a 120 volt 60 Hz, AC only,
15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When
installing this appliance, observe all applicable codes and ordinances.
A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord.
Where a two-pronged wall-receptacle is encountered, it is the personal responsibility and obligation of the customer to