R-330H
20
1. CARRY OUT 3D CHECKS.
2. Disconnect the high voltage fuse from the power
transformer.
3. Disconnect the high voltage wire of high voltage rectifier
assembly from the magnetron.
4. Disconnect the filament lead (short one) of the power
transformer from the high voltage capacitor.
5. Remove the one (1) screw holding capacitor holder to
bottom plate.
6. Remove one (1) screw holding high voltage rectifier
assembly to capacitor holder.
7. Disconnect rectifier terminal from capacitor.
High voltage rectifier assembly is now free.
8. Disconnect the high voltage fuse from the capacitor.
The high voltage fuse is now free.
9. Remove capacitor holder. Capacitor is now free.
CAUTION: WHEN REPLACING HIGH VOLTAGE REC-
TIFIER AND HIGH VOLTAGE CAPACITOR,
GROUND SIDE TERMINAL OF THE HIGH
VOLTAGE RECTIFIER MUST BE SECURED
FIRMLY WITH A GROUNDING SCREW.
MAGNETRON REMOVAL
Removal
1. CARRY OUT 3D CHECKS.
2. Disconnect all wire leads from magnetron.
3. Remove the one (1) screw holding the chassis support
to the magnetron.
4. Release the chassis support from the hole of the oven
cavity front flange.
5. Remove the two (2) screws holding air duct to magnetron
and oven cavity top plate.
6. Remove the air duct from oven.
7. Carefully remove the four (4) screws holding magnetron
to waveguide flange.
8. Remove magnetron with care so that magnetron
antenna is not hit by any metal object around antenna.
9. Now, the magnetron is free.
Reinstallation
1. Reinstall the magnetron to waveguide flange with the
four (4) screws.
2. Reinstall the air duct to the oven cavity top plate and the
magnetron with two (2) screws.
3. Insert the end of the chassis support into the hole of the
oven cavity front flange.
4. Hold the other end of the chassis support to the
magnetron with the one (1) screw.
5. Reconnect the wire leads to the magnetron. Refer to
"PICTORIAL DIAGRAM".
6. Reinstall outer case and check that the oven is operating
properly.
CAUTION: WHEN REPLACING MAGNETRON, BE
SURE THE R.F. GASKET IS IN PLACE AND
MOUNTING SCREWS ARE TIGHTENED
SECURELY.
1. CARRY OUT 3D CHECKS.
2. Push the lever of positive lock
®
connector.
3. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU.
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
Figure C-1. Positive lock
®
connector
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
HIGH VOLTAGE RECTIFIER, HIGH VOLTAGE FUSE AND HIGH VOLTAGE CAPACITOR REMOVAL
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads from control unit.
3. Remove the one (1) screw holding the control panel
CONTROL PANEL ASSEMBLY REMOVAL
assembly to the oven flange.
4. Slide the control panel assembly upward and remove it.
5. Now, individual components can be removed.
Removal
1. CARRY OUT 3D CHECKS.
2. Remove the control panel assembly, referring to chapter
of CONTROL PANEL ASSEMBLY REMOVAL.
CONTROL UNIT ASSEMBLY REPLACEMENT
3. Tear away the graphic sheet from the control panel
frame and control unit assembly
4. Remove the two (2) screws holding the control unit
assembly to the control panel frame.
and filament leads of transformer to magnetron and
high voltage capacitor. And reconnect the high voltage
fuse to the power transformer. Refer to "PICTORIAL
DIAGRAM".
4. Reinstall outer case and check that oven is operating
properly.