o protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on
the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
The rated AC voltage is not present between
Check supply voltage and oven power cord.
the normal open terminal of the relay RY1
and the normal open terminal of the relay RY2.
2
The rated AC voltage is present to primary
Low voltage transformer or secondary circuit defective.
side of low voltage transformer.
Check and replace control unit assembly.
3
Only pattern at "a" is broken.
*Insert jumper wire J1 and solder.
4
Pattern at "a" and "b" are broken.
*Insert the coil RCILF2003YAZZ between "c" and "d".
NOTE: *At the time of making these repairs, make a
visual inspection of the varistor. Check for burned
damage and examine the transformer with a
tester for the presence of layer short-circuit
(check the primary coil resistance). If any
abnormal condition is detected, replace the
control unit assembly.
CARRY OUT 4R CHECKS.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
N
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING BOARD
(PWB) IS OPEN
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage.
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated ............... Defective relay.
DC. voltage not indicated ......... Check diode which is connected to the relay coil. If diode is good,
control unit is defective.
RELAY SYMBOL
OPERATIONAL VOLTAGE
CONNECTED COMPONENTS
RY1
APPROX. -11.8V D.C.
Oven lamp / Turntable motor / Cooling fan motor
RY2
APPROX. -10.5V D.C.
Power transformer
CARRY OUT 4R CHECKS.
d
a
b