R307KW
8 – 6
[13] Procedure L: RELAY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin No. 1 of the 3 pin connector (A) and the normal open terminal of the relay RY2 on the con-
trol unit with an A.C. voltmeter.
The meter should indicate 120 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated ................. Defective relay.
DC. voltage not indicated ........... Check diode which is connected to the relay coil. If diode is good, control unit is defective.
8. If any abnormal condition is defected, replace the control unit.
9. Disconnect the power supply cord and then remove outer case.
10.Open the door and block it open.
11.Discharge high voltage capacitor.
12.Reconnect all leads removed from components during testing.
13.Re-install the outer case (cabinet).
14.Reconnect the power supply cord after the outer case is installed.
15.Run the oven and check all functions.
[14] Procedure M: DEFROST TEST
WARNING:
The oven should be fully assembled before following procedure.
1. Place one cup of water in the center of the turntable tray in the oven cavity.
2. Close the door, touch the “DEFROST“pad once. And then touch the number pad 2.
3. Touch the number pad 5 and then touch the start pad.
4. The oven is in Defrost cooking condition.
5. The oven will operate as follows.
6. If improper operation is indicated, the control unit is probably defective and should be checked.
[15] Procedure N: FOIL PATTERN ON THE PRINTED WIRING BOARD TEST
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on the PWB, this foil pattern acts as a fuse.
1. Foil pattern check and repairs.
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Follow the troubleshooting guide given below for repair.
RELAY SYMBOL
OPERATIONAL VOLTAGE
CONNECTED COMPONENTS
RY1
Approx. 12.5V D.C.
Oven lamp / Turntable motor / Cooling fan motor
RY2
Approx. 11.2V D.C.
Power transformer
MENU
1ST STAGE
2ND STAGE
3RD STAGE
Steaks/Chops
LEVEL
TIME
LEVEL
TIME
LEVEL
TIME
0.5lb
70%
17sec.
60%
27sec.
30%
40sec.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
Only pattern at “a” is broken.
*Insert jumper wire J1 and solder.
2
Pattern at “a” and “b” are broken. *Insert the coil RCILF2003YAZZ between “c” and “d”.