A31585,R22GV,/22GT/23GT/24GT/25JT
5
Receptacle Box Cover
3-Pronged plug
(6-15P) R-24GT
(6-20P) R-25JT
3-Pronged, Receptacle
(6-20R)
230 V
230 V
208 V
208 V
(A)
Receptacle Box Cover
3-Pronged plug
(6-15P)
3-Pronged, Receptacle
(6-15R)
GROUNDING INSTRUCTIONS
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord
having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded.
WARNING
–
Improper use of the grounding plug can result in a risk of electric shock. The electrical
requirements are 120 Volt, 60 Hz AC only, 20 Amp or more (R-22GV,R-22GT); 230/208 Volt, 60 Hz, AC
only, 15 Amp or more (R-23GT) and 20 Amp or more (R-24GT, R-25JT) fused electrical supply. It is
recommended that a separate circuit serving only this appliance be provided. When installing this
appliance, observe all applicable codes and ordinances. If it is necessary to use an extension cord, use
only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that will accept the
plug on the appliance. The marked rating of the extension cord should be AC 120 Volt 20 Amp (R-22GV,R-
22GT), AC 230/208 Volt 15 Amp (R-23GT), AC230/208 Volt 20 Amp (R-24GT, R-25JT). Consult a
qualified electrician or serviceman if the grounding instructions are not completely understood or if doubt
exists as to whether the appliance is properly grounded.
230/208V 15A
R-23GT
230/208V 20A
R-24GT, R-25JT
120V 20A
R-22GV,R-22GT
Receptacle Box Cover
3-Pronged plug
(5-20P)
3-Pronged, Receptacle
(5-20R)
Radio or TV Interference
Should there be any interference caused by the
microwave oven to your radio or TV, check that
the microwave oven is on a different electrical
circuit, relocate the radio or TV as far away from
the oven as feasible or check position and signal
of receiving antenna.
VOLTAGE SELECT
The R-23GT, the R-24GT and the R-25JT have been
preset for 230V operation.
If you need to change this oven for 208V operation,
follow instructions below.
1. Unplug oven.
2. Remove one screw(A) from the Voltage Select
Cover located on back of the oven near the
bottom.
3. Remove the Voltage Select Cover and rotate 180
degrees.
4. Reinstall the Voltage Select Cover using one
screw(A) removed in Step 2.
5. Plug power cord into wall outlet.
Your oven is now ready for 208V, 60Hz operation.
Note: If “EE4” or “EE5” appear in the lighted digital