46
E
Control item
Command
Direction
Parameter
Reply
Control/Response contents
*
ADJUSTMENT LOCK
ALCK
WR
0 - 2
0 - 2
0: OFF
Yes
LED
OFLD
WR
0
0
LED ON
Yes
1
1
LED OFF
SCREEN MOTION
SCSV
WR
0
0
SCREEN MOTION OFF
Yes
1
1
SCREEN MOTION ON
MOTION TIME 1
MTIM
WR
0 - 20
0 - 20
Yes
MOTION TIME 2
MINT
WR
10 - 990
10 - 990
The time is set in units of 10 seconds.
Power On Delay
PWOD
WR
0
0
Power On Delay OFF
Yes
1 - 60
1 - 60
Power On Delay ON
LANGUAGE
LANG
WR
14
14
ENGLISH
Yes
1
1
DEUTSCH
2
2
FRANÇAIS
3
3
ITALIANO
4
4
ESPAÑOL
5
5
РУССКИЙ
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
Yes
1
Internal temperature abnormal (Standby mode)
2
Internal temperature abnormal (Temperature is normal now, but it was abnormal
during operation.)
3
Internal temperature abnormal (Brightness of the backlight decreases.)
4
Temperature sensor abnormal
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
Yes
R
0
No detectable error has occurred
1
Standby mode by remote control
2
Standby mode by power switch on the monitor
3
Standby mode by RS-232C
4
Waiting mode by No Signal/Out of Timing (Incl: VESA DPMS/DMPM)
6
Standby mode by abnormal temperature
7
Standby mode by OFF TIMER function
Controlling the Monitor with a PC