SIM424-003 

 

2

GENERAL WARNING 

1. 

PV modules are heavy. Handle with care. 

2. 

Before  you  attempt  to  install,  wire,  operate  and  maintain 
the  PV  module,  please  make  sure  that  you  completely 
understand  the  information  described  in  this  installation 
manual. 

3. 

Contact with electrically active parts of a PV module such 
as terminals can result in burns, sparks and lethal shock 
whether the PV modules are connected or not. 

4. 

PV  modules  produce  electricity  when  the  sufficient 
sunlight  or  other  sources  illuminate  the  module  surface. 
When  the  modules  are  connected  in  series,  voltage  is 
cumulative. When the modules are connected in parallel, 
current  is  cumulative.  As  a  result,  a  large-scale  PV 
system can produce high voltage and current which could 
present  an  increased  hazard  and  may  cause  serious 
injury or death. 

5. 

Do not connect the PV modules directly to the loads such 
as  motor  since  the  variation  of  the  output  power 
depending on the solar irradiation causes damage for the 
connected motor. 
1:  In  the  case  of  a  brushless  motor,  the  lock  function 

becomes  active  and  the  hall  IC  is  most  likely  to  be 
damaged.  

2: In the case of a brush type motor, the coil is most likely 

to be damaged. 

6. 

In case of snow build-up, snow would slide easier on the 
smooth surface of the module than other parts of the roof. 
Snow may suddenly slide, fall off the roof and hit nearby 
objects/areas.  Take  preventive  measures  (e.g.  snow 
stopper)  when  there  is  possible  risk  such  case  would 
cause an injury or a damage. 

 

GENERAL SAFETY 

1. 

Consult local codes and other applicable laws concerning 
required  permits  on  regulations  for  installation  and 
inspection requirements. 

2. 

Before  installing  a  PV  module,  contact  appropriate 
authorities to determine permit, installation and inspection 
requirements that should be followed. 

3. 

Install PV modules and ground frames in accordance with 
applicable rules and regulations. 

4. 

PV  modules  should  be  installed  and  maintained  by 
qualified  personnel.  Only  installer/servicer  personnel 
should have access to the PV module installation site. 

5. 

No matter where the PV modules are installed, either roof 
mounted  construction  or  any  other  type  of  structures 
above the ground, appropriate safety practices should be 
followed  and  required  safety  equipment  should  be  used 
in  order  to  avoid  possible  safety  hazards.  Note  that  the 
installation of some PV modules on roofs may require the 
addition  of  fireproofing,  depending  on  local  building/fire 
codes. 

6. 

In  the  case  that  the  PV  modules  are  non-integral  type, 
the module is to be mounted over a fire resistant roof. 

7. 

Use PV modules with the same cell size within series. 

8. 

Follow  all  safety  precautions  of  other  components  that 
are used in the system. 

9. 

In order to avoid a risk of injury or electrical shock, do not 
allow  anyone  to  approach  the  PV  module  if  the  person

 

has  little  knowledge  on  PV  module  or  on  the  measures 
that should be taken when PV modules are damaged. 

10.  Do not shade portions of the PV module surface from the 

sunlight for a long time. The shaded cell may become hot 
(hot  spot  phenomenon)  which  results  in  solder  joints 
peeling  off.  Shading  causes  drop  in  generated  power 
and/or operation failure of the PV modules. 

11.  Do not clean the glass surface with chemicals. Do not let 

water  collect  on  the  glass  surface  for  a  long  time.  This 
creates  a  risk  of  white  efflorescence  (glass  disease) 
which may result in the deterioration of energy generation. 

12.  Do  not  install  the  PV  module  horizontally.  It  may  cause 

dirt or white efflorescence (glass disease) due to water. 

13.  Do not cover the water drain gap of the frame. There is a 

risk  of  frost  damage  when  the  frame  is  filled  with  water 
cumulation. 

14.  If there is a risk of sliding snow, an appropriate measure 

has to be taken so that PV module frames on lower edge 
of PV modules will not be damaged. 

15.  Do  not  expose  PV  module  to  sunlight  concentrated  with 

mirrors, lenses or similar means. 

16.  Turn  off  inverters  and  circuit  breakers  immediately, 

should a problem occur. 

17.  In case the glass surface of a PV module is broken, wear 

goggles and tape the glass to keep the broken pieces in 
place. 

18.  A  defective  PV  module  may  generate  power  even  if  it  is 

removed from the system. It may be dangerous to handle 
the  PV  module  while  exposed  to  sunlight.  Place  a 

defective  PV  module  in  a  carton  so  PV  cells  are 
completely shaded. 

19.  In  case  of  series  connection,  the  maximum  open  circuit 

voltage must not be greater than the specified maximum 
system voltage. The voltage is proportional to the number 
of series. In case of parallel connection, please be sure to 
take  proper  measure  (e.g.  fuse  for  protection  of  module 
and  cable  from  over  current,  and/or  blocking  diode  for 
prevention  of  unbalanced  strings  voltage)  to  block  the 
reverse  current  flow.  The  current  may  easily  flow  in  a 
reverse direction

20.  Keep modules away from children. 
 

HANDLING SAFETY  

1. 

Do  not  cause  an  excessive  load  on  the  surface  of  PV 
module  or  twist  the  frame.  The  glass  surface  can  easily 
break. 

2. 

Do  not  stand  or  step  on  the  PV  module.  The  surface 
glass of PV module is slippery. 

3. 

Do  not  hit  or  put  excessive  load  on  the  glass  or  back 
sheet. The PV cell is very thin and can be easily broken. 

4. 

Do not scratch or hit at the back sheet. The back sheet is 
vulnerable. 

5. 

Do not damage the junction box or do not pull the cables. 
The junction box can crack and break. 

6. 

Never touch junction box or the end of output cables with 
bare hands when the PV module is irradiated. Cover the 
surface  of  PV  module  with  cloth  or  other  suitable 
sufficiently opaque material to isolate the PV module from 
incident  light  and  wear  rubber  gloves  when  handling  the 
wires to avoid electric shock. 

7. 

Do not scratch the output cable or bend it with force. The 
insulation  of  output  cable  can  break  and  may  result  in 
electricity leakage or shock. 

8. 

Do  not  pull  the  output  cable  excessively.  The  output 
cable may unplug and cause electricity leakage or shock. 

9. 

Do  not  drill  holes  in  the  frame.  It  may  compromise  the 
frame strength and cause corrosion. 

10.  Do not scratch the insulation coating of the frame (except 

for  grounding  connection).  It  may  cause  corrosion  of  the 
frame or compromise the framework strength. 

11.  Do not touch the PV module with bare hands. The frame 

of PV module has sharp edges and may cause injury. 

12.  Do  not  drop  PV  module  or  allow  objects  to  fall  down  on 

the PV module. 

13.  Do not concentrate sunlight artificially on the PV module. 
14.  Do not hold the PV module on one side. The frame may 

bend or twist. Hold the PV module at opposite sides. 

15.  Do not touch the anti-reflective coated glass since finger 

prints and/or stains can be easily left on the glass surface. 

 

INSTALLATION SAFETY  

1. 

Always wear protective head gear, insulating gloves and 
safety  shoes  (with  rubber  soles).  Do  not  wear  metallic 
jewellery to prevent electric shock during installation. 

2. 

Keep  the  PV  module  packed  in  the  carton  until 
installation. 

3. 

Do  not  touch  the  PV  module  unnecessarily  during 
installation.  The  glass  surface  and  the  frames  get  hot. 
There is a risk of burn, or electric shock. 

4. 

Do not work under rain, snow or windy conditions. 

5. 

Use dry insulated tools. 

6. 

Do not drop tools or hard objects on PV modules 

7. 

When  working  at  heights,  wear  a  safety  belt  and  take 
care not to drop any items (e.g., PV module or tools). 

8. 

Make  sure  flammable  gases  are  not  generated  near  the 
installation site. 

9. 

Completely cover the PV module surface with an opaque 
material during PV module installation and wiring. 

10.  Plug  in  the  connector  tight  and  ensure  the  wiring  work.

 

Make  sure  that  the  connectors  have  been  locked  by  a 
snap-in latch. Any treatments over the connectors  which 
may allow to unlock the snap-in latch shall not be done. 

11.  Due  to  the  risk  of  electrical  shock,  do  not  perform  any 

work if the terminals of PV module are wet. 

12.  Do  not  touch  the  junction  box  and  the  end  of  output 

cables,  the  cable  ends  (connectors)  ,  with  bare  hands 
during  installation  or  under  sunlight,  regardless  of 
whether  the  PV  module  is  connected  to  or  disconnected 
from the system. 

13.  Do  not  unplug  the  connector  if  the  system  circuit  is 

connected to a load. 

14.  Do  not  stomp  on  the  glass  at  work.  There  is  a  risk  of 

injury or electric shock if glass is broken. 

 

15.  Do not  work alone (always  work as a team of 2 or more 

people). 

16.  Do  not  damage  the  back  sheet  of  PV  modules  when 

setting the equipotential bonding by bolts. 

Содержание NQ-R258H

Страница 1: ... orientation long frame side facing down 13 As a result of sliding snow the mechanical load increases when the number of module rows in the matrix of a PV installation increases When mounting the module in the portrait orientation for more than 3 rows the accumulated snow load may cause the lower edge of the module frame to deform Take necessary measures e g snow stopper to avoid possible damage 1...

Страница 2: ... keep the broken pieces in place 18 A defective PV module may generate power even if it is removed from the system It may be dangerous to handle the PV module while exposed to sunlight Place a defective PV module in a carton so PV cells are completely shaded 19 In case of series connection the maximum open circuit voltage must not be greater than the specified maximum system voltage The voltage is...

Страница 3: ...es connected in series 7 GROUNDING The frame grounding must consider the local requirement and regulation at the installation site When grounding is required please refer to below example connection Figure 3 Please be careful in arranging the system ground so that the removal of one module from the circuit will not interrupt the grounding of any other modules The modules should be grounded to the ...

Страница 4: ...ically and electrically compatible with Multi Contact AG PV KST4 PV KBT4 as of 23 October 2013 To extend the module connecting leads only use Multi Contact AG PV KST4 PV KBT4 or SMK Corporation connectors under the same series 3 WARNING Keep all MODULES and electriacal CONNECTORS clean dry before installation 4 Disposal Dispose photovoltaic modules properly For Information about the proper disposa...

Отзывы: