E-49
Maintenance &
Tr
oubleshooting
Lamp/Maintenance Indicators
Maintenance Indicators
TEMPERATURE
WARNING
indicator
LAMP
REPLACEMENT
indicator
POWER
indicator
• The warning lights on the projector indicate problems
inside the projector.
• There are two warning lights: a TEMPERATURE
WARNING indicator which warns that the projector is
too hot, and a LAMP REPLACEMENT indicator which
lets you know when to change the lamp.
• If a problem occurs, either the TEMPERATURE
WARNING indicator or the LAMP REPLACEMENT
indicator will illuminate red. After turning off the power,
follow the procedures given below.
Problem
• Lamp has been used for over 1,900
hours.
• Lamp has been used for over 2,000
hours.
Possible Solution
• Purchase a replacement lamp unit
(lamp cage/module) of the current
type BQC-XGC40XU/1 from your
nearest Authorized Sharp Industrial
LCD Products Dealer or Service
Center.
• Replace the lamp. (See pages 50
and 51.) If you wish, you may have
the lamp replaced at your nearest
Authorized Sharp Industrial LCD
Products Dealer or Service Center.
Condition
The LAMP REPLACEMENT
indicator illuminates red, and
“LAMP” and “ ” will flash in yellow
in the lower-left corner of the
picture.
The power will automatically turn
off and the projector will enter
standby mode.
“LAMP” and “ ” will flash in red in
the lower-left corner of the picture,
and the power will turn off.
Problem
• Blocked air intake.
• Clogged air filter.
• Cooling fan breakdown.
• Internal circuit failure.
• Burnt-out lamp.
• Lamp circuit failure.
• Lamp has been used for
over 1,900 hours.
• The bottom filter cover is
open.
Maintenance Indicator
The internal
temperature is
abnormally high.
TEMPERATURE
WARNING indicator
LAMP REPLACE-
MENT indicator
POWER indicator
The lamp does not
illuminate.
The lamp requires
replacement.
The POWER
indicator flashes in
red when the
projector is on.
Condition
Possible Solution
• Relocate the projector to an area with
proper ventilation.
• Clean the filter.
(See page 47.)
• Take the projector to your nearest
Authorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
• Carefully replace the lamp. (See pages 50
and 51.)
• Take the projector to your nearest
Authorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
• Securely install the bottom filter cover.
• If the TEMPERATURE WARNING indicator illuminates, follow the above possible solutions and then wait until the projector has cooled down
completely before turning the power back on. (At least 5 minutes.)
• If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be triggered, preventing
the power from going on. Should this occur, take the power cord out of the wall outlet and put it back in again.
Lamp
The lamp in this projector operates for approximately 2,000 cumulative hours, depending on the usage environ-
ment. It is recommended that the lamp be replaced after 1,900 cumulative hours of use or when you notice a
significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen
Display (see page 43).
CAUTION
• Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.
• As the usage environment can vary significantly, the projector lamp may not operate for 2,000 hours.
Содержание Notevision XG-C40XU
Страница 12: ...E 11 Setup Connections Setup Connections ...
Страница 63: ...SHARP CORPORATION ...