MX-M264U SIMULATION 6 – 13
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check the output of the transfer
charger output voltage.
Section
Process (Transport)
Operation/Procedure
1)
Select a target item to be adjusted with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [EXECUTE] key.
The set value is saved and the voltage corresponding to the
set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display
Content
Setting
range
Default value
26cpm
machine
31cpm
machine
35cpm
machine
A
+V1 F
Transfer
bias
reference
value
Standard
paper
W
Between
papers
Single
A-1: W, +V1 F (Between
papers), Standard paper
front surface
(Single/Duplex)
0 - 255
5
5
5
B
+V1 R
Duplex
A-2: W, +V1 R (Between
papers), Standard paper
back surface (Duplex)
0 - 255
5
5
5
C
+V2 F
Paper
Single
A-3: W, +V2 F, Standard
paper front surface
(Single/Duplex)
0 - 255
14
18
20
D
+V2 R
Duplex
A-4: W, +V2 R, Standard
paper back surface
(Duplex)
0 - 255
12
16
14
E
+V1 S-F
Standard
paper
N1jp
Between
papers
Single
B-1: N1jp, +V1 S-F
(Between papers),
Standard paper front
surface (Single/Duplex)
0 - 255
5
5
5
F
+V1 S-R
Duplex
B-2: N1jp, +V1 S-R
(Between papers),
Standard paper back
surface (Duplex)
0 - 255
5
5
5
G
+V2 S-F
Paper
Single
B-3: N1jp, +V2 S-F,
Standard paper front
surface (Single/Duplex)
0 - 255
14
18
20
H
+V2 S-F
Duplex
B-4: N1jp, +V2 S-F,
Standard paper back
surface (Duplex)
0 - 255
14
18
20
I
+V1 XS-F
Standard
paper
N2jp
Between
papers
Single
C-1: N2jp, +V1 XS-F
(Between papers),
Standard paper front
surface (Single/Duplex)
0 - 255
5
5
5
J
+V1 XS-R
Duplex
C-2: N2jp, +V1 XS-R
(Between papers),
Standard paper back
surface (Duplex)
0 - 255
5
5
5
K
+V2 XS-F
Paper
Single
C-3: N2jp, +V2 XS-F,
Standard paper front
surface (Single/Duplex)
0 - 255
14
18
20
L
+V2 XS-R
Duplex
C-4: N2jp, +V2 XS-R,
Standard paper back
surface (Duplex)
0 - 255
14
18
20
M
+V1 THICK
Heavy
paper
>LTR
Between papers
D-1: > LTR, +V1 THICK
(Between papers),
Heavy paper
0 - 255
5
5
5
N
+V2 THICK
Paper
D-2: > LTR, +V2 THICK,
Heavy paper
0 - 255
10
14
16
O
+V1 THICK S
LTR
Between papers
E-1:
LTR, +V1 THICK S
(Between papers),
Heavy paper
0 - 255
5
5
5
P
+V2 THICK S
Paper
E-2:
LTR, +V2 THICK
S, Heavy paper
0 - 255
12
14
16