MX-M264U SIMULATION 6 – 37
Code descriptions
List of destination groups
35cpm machine
R
HL_UM WARMUP_120H
TH_LM set value when Warm-Up
at 120
C or above
70 - 220
130
180
180
180
190
190
190
190
S
HL_US WARMUP_120H
TH_US set value when Warm-Up
at 120
C or above
70 - 220
130
180
180
180
190
190
190
190
T
HI_WARMUP_TIME
R, S applying time (Timer from
completion of Ready)
0 - 255
0
0
0
0
0
0
0
0
U
HI_WU_FM_ON_TMP
FM prior rotation start TH_US
when Warm-Up at alpha
C or
above
0 - 220
0
0
0
0
0
0
0
0
V
HI_WU_END_TIME
Warm-Up completion time when
Warm-Up at alpha
C or above
0 - 60
18
18
18
18
18
18
18
18
W
HI_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1
when Warm-Up at alpha
C or
above
30 - 220
130
180
180
180
190
190
190
190
X
HI_WARMUP_BORDER
Threshold value alpha to which U -
W is applied
1 - 119
60
60
60
60
60
60
60
60
Y
LO_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1
when Warm-Up at alpha
C or
below
70 - 220
130
180
180
180
190
190
190
190
Z
JOBEND_FUMON_TIME
After rotating time when a job is
completed
0 - 60
0
0
0
0
0
0
0
0
AA
HI_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2
when Warm-Up at alpha
C or
above
70 - 220
130
180
180
180
190
190
190
190
AB
LO_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2
when Warm-Up at alpha
C or
below
70 - 220
130
180
180
180
190
190
190
190
Item/Display
Content
Setting
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group
Destination
Group A
JAPAN
–
–
–
–
Group B
U. S. A
CANADA
INCH
–
–
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
–
–
–
–
Item/Display
Content
Setting
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
Ready standby TH_UM set value
70 - 220
185
185
185
185
190
190
190
190
B
HL_US READY
Ready standby TH_US set value
70 - 220
180
180
180
180
185
185
185
185
C
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM
set value
70 - 220
195
200
195
200
195
200
195
200
D
HL_US PLAIN PAPER BW
Black-White plain paper TH_US
set value
70 - 220
195
200
195
200
195
200
195
200
E
WARMUP FUMON HL_UM T
Fusing motor pre-rotation start
TH_US set value
0 - 200
0
0
0
0
0
0
0
0
F
WARMUP FUMOFF HL_UM T
Fusing motor previous rotation
complete time
0 - 60
0
0
0
0
0
0
0
0
G
WARMUP END TIME
Warm-up complete time
0 - 20
18
18
18
18
18
18
18
18
H
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 220
200
200
200
200
I
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 220
200
200
200
200
J
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 220
195
195
195
195
K
HL_US OHP PAPER
OHP-TH_US set value
70 - 220
195
195
195
195
L
HL_UM E-STAR
Preheating TH_UM set value
70 - 220
95
95
95
95
95
95
95
95
M
HL_US E-STAR
Preheating TH_US set value
70 - 220
95
95
95
95
95
95
95
95
N
HL_UM PRE-JOB
TH_UM set value when recovery
from Warm-Up
70 - 220
130
180
180
180
190
190
190
190
O
HL_UM WARMUP_120L
TH_UM set value when Warm-Up
at 120
C or below
70 - 220
130
180
180
180
190
190
190
190