MX-M232D (ADJUSTMENT) 12 - 7
4) After completion of warming up, shading is performed and the
current off-center adjustment value is displayed on the LCD.
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
B.Image density adjustment
(1)Copy mode (SIM46-2)
1) Set a test chart (UKOG-0162FCZZ) on the OC table as shown
below.
2) Put several sheets of A3 or 11" x 17" white paper on the test chart.
3) Execute SIM 46-2.
4) After completion of warming up, shading is performed, and the
current density level is displayed on the LCD.
Use the cross cursor to select a mode.
5) Change the set value with the 10-key to adjust the copy image
density.
6) Make a copy and check that the specification below is satisfied.
<Adjustment specification>
Adjustment
mode
SIM
Display
text
array
Set value
Specifi-
cations
Set
range
Document off-
center (OC
mode)
50-12
OC
+1
Shifted to R
side by
+0.mm.
-1
Shifted to L
side by
0.1mm.
Center ±
2.0%
1 - 99
Sim50-12 ORG. CENTER
1:OC
2:SPF(SIDE1)
3:SPF(SIDE2)
[ 1- 99]
50
50
50
50
Sim46-2 EXP LEVEL
1:AE
2:TEXT
3:PHOTO 1
1/2 [ 1- 99]
50
50
50
50
Sim46-2 EXP LEVEL
4:PHOTO 2
5:TEXT(TS)
6:AE(TS)
2/2 [ 1- 99]
50
50
50
50
Density
mode
Display
text
array
Expo-
sure
level
Sharp Gray
Chart output
Set value
Set
range
Auto-
matic
AE
-
“2” is slightly
copied.
The greater the set
value is, the darker
the density is.
The smaller the set
value is, the lighter
the density is.
1 - 99
Text
TEXT
3
“3” is slightly
copied.
Photo
(Error
diffu-
sion)
PHOTO
1
3
“2” is slightly
copied.
Photo
(Dither)
PHOTO
2
3
“2” is slightly
copied.
Toner
save
(Text)
TEXT
(TS)
3
“3” is slightly
copied.
Toner
save
(Auto-
matic)
AE(TS)
-
“2” is slightly
copied.