7
63
USER PROGRAMS
The user programs allow the parameters of certain functions to be set, changed, or
cancelled as desired.
Setting the user programs
1
Press and hold down the light (
) key for more than 5
seconds until all the alarm indicators (
,
,
,
) blink and
"
" appears in the display.
2
Use the left copy quantity (
) key to select a user program
number (For the user program numbers, see the following table.).
The selected number will blink in the left side of the display.
3
Press the start (
) key. The entered program number will be
steadily lit and the currently selected parameter number for the
program will blink on the right side of the display.
4
Select the desired parameter using the right copy quantity (
) key.
The entered parameter number will blink on the right of the display.
Program
No.
Mode
Parameters
1
Auto clear time
1
10 sec., 2
30 sec., *3
60 sec.,
4
90 sec., 5
120 sec., 6
OFF
2
Preheat mode
*1
30 sec., 2
60 sec., 3
5 min.,
4
30 min., 5
60 min., 6
120 min.,
7
240 min.
3
Auto power shut- off
mode
*1
ON, 2
OFF
4
Auto power shut- off
timer
*1
5 min., 2
30 min., 3
60 min.,
4
120 min., 5
240 min.
6
SPF automatic
original discharge
time (Only operates
when an SPF is
installed.)
1
5 min., *2
30 min.,
3
60 min., 4
120 min.,
5
240 min., 6
OFF
10
Resolution of AUTO
& MANUAL mode
*1
300dpi, 2
600dpi
13
Memory for printer
1
30%, 2
40%, *3
50%,
4
60%, 5
70%
21
Reset factory
1
YES, *2
NO
22
Sort auto select
*1
ON, 2
OFF
24
Prevention of OC
copies when the
original cover/SPF
is up function
*1
ON, 2
OFF
Содержание MX-B200
Страница 90: ...SHARP ELECTRONICS Europe GmbH Sonninstraße 3 D 20097 Hamburg ...
Страница 91: ...EN1 OPERATION GUIDE ...