MD-MS701W/MS702
– 28 –
: Temp setting menu
: TEMP setting
: setting
§ §
: Temperature code
: TEMP A/D input value
: Measurement value
PLAY
T e m p
TEMP Setting
T M § §
T p i n
SKIP UP
SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In the specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific state the setting changes in the range of "00h to FFh"
when the [VOL UP/DOWN] key is pressed.
: Adjustment setting menu
: Adjustment COUT level reference value
: setting
: Focus ATT reference value
: setting
: Tracking ATT reference value
: setting
: TCRS ATT reference value
: setting
: Focus balance factor
: setting
PLAY
A D J S E T
Adjustment Setting
C O K
F A T
SKIP UP
SKIP DOWN
T A T
SKIP UP
SKIP DOWN
C A T
SKIP UP
SKIP DOWN
F A B
SKIP UP
SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific setting display state the setting change digit changes
when the [P-MODE] key is pressed.
1st digit (initial value)
2nd digit
P-MODE
P-MODE
* In the specific state the setting changes in the range of "0h to Fh"
when the [VOL UP/DOWN" key is pressed.
: Digital EQ setting menu
: High-reflection pit section Digital EQ tap factor A, D
: setting
: High-reflection pit section Digital EQ tap factor B, C
: setting
: High-reflection pit section Autolevel slicer gain
: setting
: High-reflection pit section Autolevel slicer slice level offset
: setting
: Lows-reflection pit section Digital EQ tap factor A, D
: setting
: Low-reflection groove section digital EQ tap factor A, D
: setting
: Lows-reflection pit section Digital EQ tap factor B, C
: setting
: Low-reflection pit section Autolevel slicer gain
: setting
: Low-reflection pit section Autolevel slicer slice level offset
: setting
: Low-reflection groove section digital EQ tap factor B, C
: setting
: Low-reflection groove section Autolevel slicer gain
: setting
: Low-reflection groove section Autolevel slicer slice level offset
: setting
: Digital EQ-related other settings
: setting
PLAY
D E Q S E T
Digital EQ Setting
H Q 1
H Q 2
SKIP UP
SKIP DOWN
H S G
SKIP UP
SKIP DOWN
H S O
SKIP UP
SKIP DOWN
L Q 1
SKIP UP
SKIP DOWN
L Q 2
SKIP UP
SKIP DOWN
L S G
SKIP UP
SKIP DOWN
L S O
SKIP UP
SKIP DOWN
G Q 1
SKIP UP
SKIP DOWN
G S O
SKIP UP
SKIP DOWN
D Q R
SKIP UP
SKIP DOWN
G Q 2
SKIP UP
SKIP DOWN
G S G
SKIP UP
SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific setting display state the setting change digit changes
when the [P-MODE] key is pressed.
1st digit (initial value)
2nd digit
P-MODE
P-MODE
* In the specific state the setting changes in the range of "0h to Fh"
when the [VOL UP/DOWN" key is pressed.