MD-DR470H/MD-DR480H
– 10 –
* Pre-mastered disc
Continuous playback
[ S Q
]
(SUBQ address indication)
↓
Continuous playback (C1 error indication)
[ C E
]
↓
Continuous playback
[ S Q
]
(SUBQ address indication)
* Recordable disk
Continuous playback
[ A P
]
(ADIP address indication)
↓
Continuous playback (C1 error indication)
[ C E
]
↓
Continuous playback (ADIP error indication) [ A E
]
↓
Continuous playback
[ b
]
(Integrating jitter indication)
↓
Continuous playback
[ A P
]
(ADIP address indication)
6. REC Mode
• When the STOP button is pressed while the REC menu appears, or
in the REC mode or continuous record mode, the mode changes to
the TEST mode stop state.
• Whenever the DISP button is pressed in the REC menu, the target
address changes as follows.
0032
→
03C0
→
0700
→
08A0
→
0950
→
0032
→
•••
When the PLAY button is pressed while a target address is dis-
played, continuous playback is performed after searching that
address.
• Whenever the REC button is pressed in the REC mode target
address is displayed, the digit which is changed by the /
– button changes as follows.
0032
→
0032
→
0032
→
0032
→
•••
• When the FORWARD button is pressed in the REC mode target
address is displayed, the digit of address specified by the REC
button is set to +1h. (0 to F)
• When the REVERSE button is pressed in the REC mode target
address is displayed, the digit of address specified by the REC
button is set to -1h. (0 to F)
* When the FORWARD/REVERSE button is held down, the setting
changes continuously, one cycle being 100 ms.
• When the /– button is pressed in the REC mode or
continuous record mode, the laser record power changes.
(Servo gain changes also according to record power.)
* After the laser record power is indicated for one second, the
address indication is restored.
[ R P W _
]
•
: Address
•
: Laser power cord
• Operation is disabled if the premastered disc or disc is in miserase-
protected state.
7. NORMAL Mode
• When the STOP button is pressed while the NORMAL menu
appears, the mode changes to the TEST mode stop state.
• Indication during operation Indication of memory capacity on main
unit LCD [
_ _ ] + Level meter
: Internal mode
: Address (Cluster section)
: Address (Sector section)
• Selection of sound volume, BASS, etc. is possible. (without indica-
tion)
• Recording is also possible.
• If the STOP button is pressed during operation in the NORMAL
mode, the NORMAL mode is cancelled, and the power is turned off.
8. E_DATA display Mode
• Reversing when REVERSE button is pressed.
• When the STOP button is pressed while the error data indication
menu appears or during error data indication, the mode changes to
the TEST mode stop state.
• Error data 0 is the latest error.
• Error which occurred in the TEST mode is also stored in the memory.
• When the DISP button is pressed while the error data indication
menu appears, the error data is initialized.
[ C L E A R _ ]
: Error Code
13 h : Adjustment servo retraction excessive retrial
16 h : C. IN detection time-over
17 h : A, B, E, F, and TCRSO offset measurement value out of
tolerable range
21 h : Focus retraction completion allowable time-over
22 h : Unable to activate the spindle motor
23 h : Track search completion allowable time-over
32 h : P-TOC read failure
42 h : U-TOC read failure
44 h : U-TOC write data write disabled/read check error
45 h : U-TOC write test failure
52 h : SD write data write disabled
72 h : EEPROM data read check sum error
73 h : Record head drive disabled (by EJECT lever)
82 h : Power overvoltage detection
83 h : The temperature sensor output error
91 h : Ambient temperature is higher that the allowable temperature
Explanation of error history code
Can't READ (*)
* =
f :
Focus pulled
a :
Servo adjustment
s :
Track search
r :
TOC information reading
p :
Spindle start
Er-MD (**)
** = 80
“Er-MD 80” appears when EEPROM data cannot be read correctly
(inconsistency of data and the checksum results).
EEPROM or communication paths including the microcomputer
may be defective.
When you change EEPROM, reset data by referring to the service
manual.
** = 41
“Er-MD41” appears when writing U-TOC fails. (Only recorders)
(Reading of the written data reveals errors.)
The record head, the recording signal generator circuit including
system LSI or the pickup laser may be defective.
TOC Form (*)
* = t_ : TNO information
a_: Address information
Ln: Pointer information
(n = 0, 1, 2 or 4: UTOC sector number)
Error messages
Содержание MD-DR470H