LC
-
52DH77E/RU/S
4 – 15
MONITOR ERR STBY table
LED flashing timing chart at the time of the error
1) Power LED
Outline:
Communication/Power failure detected by the monitor microprocessor (IC2003) is stored on EEPROM, states can be confirmed in
the adjustment process mode.
Location:
Page 1/16 of the adjustment process mode: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the last page of the
adjustment process mode.
Display Error
description
02
Start-up communication error 2
Initial communication from the main CPU is not received.
03
Start-up communication error 3
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A
REQ time-out
0B
Communication error B
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C
Ending sequence time-out
0D
Communication error D
Preset start-up time-out during completion
0E
Communication error E
Download start-up time-out
0F
Communication error F
Time acquisition time-out
11
Communication error H
Regular communication time-out
16
Panel-related error
Lamp failure
1A
Other error 2
Monitor temperature failure
1D
Power supply error 1
PS_ON (AC_DET) failure
1E
Power supply error 2
D_POW (DET_12V) failure
1F
Power supply error 3
D_POW (DET_D3V3) failure
21
Power supply error 5
Panel power failure
23
Other error 3
Error standby request from the main CPU
Error type
Power LED operation (1 cycle)
Note: Pins are monitor microprocessor pins (IC2003).
Inverter/Lamp failure
Red flashes once
H: Red on
Refer to “Inverter/Lamp failure details”. OPC_LED flashes by pressing the
[MENU] key on the remote control.
L: Off
Power failure
Red flashes twice
H: Red on
Refer to “Power failure details”. OPC_LED flashes by pressing the [MENU]
key on the remote control.
L: Off
Communication
failure with main
CPU
Green flashes once
H: Green on
Refer to “Communication failure details”. OPC_LED flashes by pressing
the [MENU] key on the remote control.
Communication line failure or main CPU communication failure.
L: Off
Others
Green flashes twice
H: Green on
Refer to “Other failure details”. OPC_LED flashes by pressing the [MENU]
key on the remote control.
L: Off
300m
s
1.5sec
Содержание LC-52DH77E/RU/S
Страница 56: ...LC 52DH77E RU S 6 3 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit Side B ...
Страница 62: ...LC 52DH77E RU S 7 3 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 2 ...
Страница 63: ...LC 52DH77E RU S 7 4 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 3 ...
Страница 64: ...LC 52DH77E RU S 7 5 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 4 ...
Страница 65: ...LC 52DH77E RU S 7 6 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 5 ...
Страница 66: ...LC 52DH77E RU S 7 7 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 6 ...
Страница 67: ...LC 52DH77E RU S 7 8 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 7 ...
Страница 68: ...LC 52DH77E RU S 7 9 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 8 ...
Страница 69: ...LC 52DH77E RU S 7 10 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 9 ...
Страница 70: ...LC 52DH77E RU S 7 11 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 10 ...
Страница 71: ...LC 52DH77E RU S 7 12 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 MAIN Unit 11 ...
Страница 74: ...LC 52DH77E RU S 7 15 M E M O ...
Страница 97: ...LC 52DH77E RU S ...